Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 23:15:41 on January 24, 2002
Entry number 80634
keyword=Start_Run_1621,Run_type=production,beam_energy=2.341,beam_halfwaveplate=out,beam_polarization=,beam_raster=on,comment_text=kinematics 2A,off endpt, moff, LH2, rad, threshold=500 MeV,daq_mode=coincidence,leftarm_p=1.556,leftarm_theta=35.681,photonarm_D=12,photonarm_angle=46,photonarm_p=1260,target_name=,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 1621 at Thu Jan 24 23:15:12 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=40000,ps2=100000,ps3=100,ps4=30,ps5=1,ps6=1,ps7=65000,ps8=1024
Left Arm Q1 power supply current : 1170.44
Left Arm Q1 momentum : 1.55574
Left Arm Q1 gauss meter : 0.09967
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 669.769
Left Arm Q2 momentum : 1.55564
Left Arm Q2 gauss meter : -0.3532
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 521.985
Left Arm D1 momentum : 1.55599
Left Arm D1 NMR : 0.57587
Left Arm Q3 power supply current : 619.478
Left Arm Q3 momentum : 1.55601
Left Arm Q3 gauss meter : 0.3104
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 3.125
Left Arm Bottom VDC Current : -2.24609
Average current of the two cavities : 9.63169
Current on Unser monitor : 17.5069
Current on Upstream bcm : 9.62596
Current on Downstream bcm : 9.66701
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 10.2247
Tiefenbach Hall A energy : 2340.34
Tiefenbach Hall C energy : 5752.72
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 2343.32
MBSY3c Hall C Beam energy : 5770.08
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 97.5219
MBSY1c Bdl : 584778
Arc1 dp/p : 4.70018e-05
Arc2 dp/p : -0.0015818
Left Arm Arm Collimator : 0.065918
HacL_HPE1313A:0_Ch58 : -0.151367
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.236816
HacL_alignROLL : 0.122012
HacL_alignPITCH : -0.108047
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 35.5
Left Arm Angle Vernier : 62
Left Arm Scattering Angle : 35.6783
IPM1C12.XPOS : -0.00807954
IPM1C12.YPOS : 0.00879717
IPM1H04A.XPOS : 0.568849
IPM1H04A.YPOS : 0.721165
IPM1H04B.XPOS : -1.97251
IPM1H04B.YPOS : 1.45655
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -1.54483
Target OTR y-position : 1.42692
Target OTR x-width : 0.681481
Target OTR y-width : 0.354419
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -0.787498
Arc OTR y-position : -2.05496
Arc OTR x-width : 5.10734
Arc OTR y-width : 5.32989
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.208286