Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 05:11:08 on January 25, 2002
Entry number 80674
keyword=Start_Run_1635,Run_type=production,beam_energy=2.341,beam_halfwaveplate=out,beam_polarization=,beam_raster=on,comment_text=Acceptance Scan,off endpt,LH_noR, threshold=500 MeV,daq_mode=coincidence,leftarm_p=1.661,leftarm_theta=33.974,photonarm_D=12,photonarm_angle=46,photonarm_p=1260,target_name=LH,target_type=15LH2
Beginning-of-run EPICS data for Run Number 1635 at Fri Jan 25 05:10:52 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=20000,ps2=100000,ps3=10,ps4=10,ps5=1,ps6=1,ps7=65000,ps8=1024
Left Arm Q1 power supply current : 1249.46
Left Arm Q1 momentum : 1.66079
Left Arm Q1 gauss meter : 0.10635
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 715.282
Left Arm Q2 momentum : 1.66113
Left Arm Q2 gauss meter : -0.3771
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 558.052
Left Arm D1 momentum : 1.66102
Left Arm D1 NMR : 0.614711
Left Arm Q3 power supply current : 661.293
Left Arm Q3 momentum : 1.66105
Left Arm Q3 gauss meter : 0.3312
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : -0.0488281
Left Arm Bottom VDC Current : -2.09961
Average current of the two cavities : 17.1299
Current on Unser monitor : 25.098
Current on Upstream bcm : 17.078
Current on Downstream bcm : 17.2554
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 17.5409
Tiefenbach Hall A energy : 2340.34
Tiefenbach Hall C energy : 5753.01
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 2343.32
MBSY3c Hall C Beam energy : 5770.08
MBSY1c magnet current (amp) : 97.5219
MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 584778
Arc1 dp/p : 7.22902e-05
Arc2 dp/p : -0.00160809
Left Arm Arm Collimator : 0.0658691
HacL_HPE1313A:0_Ch58 : -0.165039
HacL_HPE1313A:0_Ch55 : 22.6074
HacL_HPE1313A:0_Ch54 : -0.200684
HacL_alignROLL : 0.154686
HacL_alignPITCH : -0.0958279
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 34.5
Left Arm Angle Vernier : -60
Left Arm Scattering Angle : 33.9752
IPM1C12.XPOS : 0.00594866
IPM1C12.YPOS : 0.0098536
IPM1H04A.XPOS : 0.569685
IPM1H04A.YPOS : 0.677349
IPM1H04B.XPOS : -1.99303
IPM1H04B.YPOS : 1.45178
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -1.53181
Target OTR y-position : 1.4251
Target OTR x-width : 0.684431
Target OTR y-width : 0.358245
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -0.818681
Arc OTR y-position : -2.06375
Arc OTR x-width : 5.1315
Arc OTR y-width : 5.33194
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.272374