• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:31:39 on January 25, 2002

    Entry number 80759

    keyword=End_of_Run_1661
    ****************************
     Run Number: 1661
     End of Run Comment:
    Run_type=optics,beam_energy=2.341,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=optic magnet=0A, 14% dead time,daq_mode=coincidence,leftarm_p=1.779,leftarm_theta=29.824,photonarm_D=7.1,photonarm_angle=56,photonarm_p=1260,target_name=optic,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=20000   ps2=100000   ps3=1   ps4=10   ps5=1   ps6=1   ps7=65000   ps8=1024   
    
    EVENTS[0]: 27517        [+]: 13550        [-]: 13462        
    TIME  [0]: 2.840 mins  [+]: 1.393 mins  [-]: 1.394 mins  
    LIVE  [0]:  35.53%      [+]:  35.47%      [-]:  35.56%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 3.4/68816.6 Hz   T2[0] : 0.0/5.6  Hz   T3[0] :428.2/428.2 Hz   T4[0] : 3.9/38.5 Hz   T5[0] :17.2/17.2 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 0.0/1319.2 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 3.4/68696.5 Hz   T2[+] : 0.0/5.4  Hz   T3[+] :430.3/430.3 Hz   T4[+] : 3.9/38.7 Hz   T5[+] :17.3/17.3 Hz   T6[+] : 1.0/1.0  Hz   T7[+] : 0.0/1321.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 3.4/68726.8 Hz   T2[-] : 0.0/5.7  Hz   T3[-] :426.4/426.4 Hz   T4[-] : 3.8/38.4 Hz   T5[-] :17.0/17.0 Hz   T6[-] : 0.9/0.9  Hz   T7[-] : 0.0/1317.2 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    586/11724756  T2[0] :      0/951      T3[0] :  72947/72947    T4[0] :    656/6564     T5[0] :   2922/2922     T6[0] :    165/165      T7[0] :      3/224760   T8[0] :    170/174466   
    T1[+] :    287/5742398  T2[+] :      0/455      T3[+] :  35973/35973    T4[+] :    323/3235     T5[+] :   1445/1445     T6[+] :     84/84       T7[+] :      1/110460   T8[+] :     83/85597    
    T1[-] :    287/5749564  T2[-] :      0/477      T3[-] :  35671/35671    T4[-] :    321/3212     T5[-] :   1423/1423     T6[-] :     74/74       T7[-] :      1/110191   T8[-] :     83/85666    
    
    AVERAGE CURRENT
    BCM x1 : 14.8760uA  BCM x3 : 14.9083uA  BCM x10: 14.9123uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -410.8 ppm     BCM u3 :   -407.4 ppm     BCM u10:   -413.8 ppm     
    BCM d1 :   -403.1 ppm     BCM d3 :   -402.7 ppm     BCM d10:   -411.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002475       BCM u3 [0]:0.002483       BCM u10[0]:0.002488       
    BCM u1 [+]:0.001214       BCM u3 [+]:0.001218       BCM u10[+]:0.001221       
    BCM u1 [-]:0.001216       BCM u3 [-]:0.00122        BCM u10[-]:0.001223       
    
    BCM d1 [0]:0.002594       BCM d3 [0]:0.002597       BCM d10[0]:0.002593       
    BCM d1 [+]:0.001273       BCM d3 [+]:0.001274       BCM d10[+]:0.001272       
    BCM d1 [-]:0.001275       BCM d3 [-]:0.001276       BCM d10[-]:0.001274       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1661 at Fri Jan 25 14:31:33 EST 2002
    Left Arm D1 momentum : 1.77911
    Left Arm arm angle : 29.8239
    Tiefenbach Hall A energy : 2340.36
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.830078
    Left Arm Bottom VDC Current : -0.683594
    Left Arm Q1 power supply current : 1338.44
    Left Arm Q1 momentum : 1.77905
    Left Arm Q1 gauss meter : 0.11381
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 766.104
    Left Arm Q2 momentum : 1.77916
    Left Arm Q2 gauss meter : -0.4038
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 599.693
    Left Arm D1 momentum : 1.7791
    Left Arm D1 NMR : 0.658378
    Left Arm Q3 power supply current : 708.294
    Left Arm Q3 momentum : 1.7791
    Left Arm Q3 gauss meter : 0.3548
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 14.4465
    Current on Unser monitor : 22.5543
    Current on Upstream bcm : 14.3833
    Current on Downstream bcm : 14.5098
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 14.5966
    MBSY1c Hall A Beam energy : 2343.32
    MBSY1c magnet current (amp) : 97.5219
    MBSY1c Bdl : 584778
    MBSY3c Hall C Beam energy : 5770.08
    Tiefenbach Hall A energy : 2340.36
    Tiefenbach Hall C energy : 5753.12
    Delta(E)/E width (MV_AI_DXWID) : 0.458607
    IPM1C12.XPOS : 0.0126864
    IPM1H04A.XPOS : 0.574798
    IPM1H04A.YPOS : 0.772284
    IPM1H04B.XPOS : -1.99105
    IPM1H04B.YPOS : 1.47025
    Left Arm Arm Collimator : 0.0655762
    HacL_HPE1313A:0_Ch58 : -0.145508
    HacL_HPE1313A:0_Ch55 : 22.6074
    HacL_HPE1313A:0_Ch54 : -0.222168
    HacL_alignROLL : 0.135772
    HacL_alignPITCH : -0.113358
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.0656738
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.47236
    Arc OTR y-position : -0.605413
    Arc OTR x-width : 4.18825
    Arc OTR y-width : 3.62439
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286