User name a-onl
Log entry time 06:46:58 on January 26, 2002
Entry number 80849
keyword=Start_Run_1695,Run_type=production,beam_energy=4.615,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=raster ON, 15LH2R , offendpoint, mon, RCS production,daq_mode=coincidence,leftarm_p=3987,leftarm_theta=15.379,photonarm_D=5.6,photonarm_angle=66,photonarm_p=,target_name=15LH2R,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 1695 at Sat Jan 26 06:46:38 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=1000000,ps2=1000000,ps3=100,ps4=200,ps5=1,ps6=20,ps7=65000,ps8=1024
Left Arm Q1 power supply current : 2999.53
Left Arm Q1 momentum : 3.98699
Left Arm Q1 gauss meter : 0.25413
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1716.96
Left Arm Q2 momentum : 3.98737
Left Arm Q2 gauss meter : -0.9029
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1494.72
Left Arm D1 momentum : 3.98701
Left Arm D1 NMR : 1.47709
Left Arm Q3 power supply current : 1587.3
Left Arm Q3 momentum : 3.98702
Left Arm Q3 gauss meter : 0.7938
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 2.00195
Left Arm Bottom VDC Current : 0.244141
Average current of the two cavities : 0.0320572
Current on Unser monitor : 8.37781
Current on Upstream bcm : 0.0363231
Current on Downstream bcm : 0.0277913
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 14.0185
Tiefenbach Hall A energy : 4615.52
Tiefenbach Hall C energy : 5752.05
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 4625.04
MBSY3c Hall C Beam energy : 5770.08
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 192.932
MBSY1c Bdl : 1.15418e+06
Arc1 dp/p : 2.78643e-05
Arc2 dp/p : -0.00182816
Left Arm Arm Collimator : 0.0656738
HacL_HPE1313A:0_Ch58 : -0.174316
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.0610352
HacL_alignROLL : 0.398703
HacL_alignPITCH : -0.108595
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 15.5
Left Arm Angle Vernier : 10
Left Arm Scattering Angle : 15.3786
IPM1C12.XPOS : -0.00102755
IPM1C12.YPOS : 0.0352981
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -1.59554
Target OTR y-position : 1.56556
Target OTR x-width : 0.488902
Target OTR y-width : 0.480598
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -0.759301
Arc OTR y-position : 0.224591
Arc OTR x-width : 4.41016
Arc OTR y-width : 3.55647
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 500
Current Readback : 500.382