• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 07:30:41 on January 26, 2002

    Entry number 80854

    keyword=Start_Run_1698,Run_type=production,beam_energy=4.615,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=raster ON, 15LH2R , offendpoint, mon, RCS production,daq_mode=coincidence,leftarm_p=3987,leftarm_theta=15.379,photonarm_D=5.6,photonarm_angle=66,photonarm_p=,target_name=15LH2R,target_type=15LH2R
    Beginning-of-run EPICS data for Run Number 1698 at Sat Jan 26 07:30:20 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the calorimeter singles based on summers
    ; PS2 for the cosmic trigger for calorimeter 
    ; PS3 for the Left spectrometer based on T3 - S1+S2
    ; PS4 for the Left spectrometer redundant trigger S1+S2 or
    ;                        based on S1+S0 or S2+S0
    ; PS5 for Coinc. trigger based on S0 and Calo
    ; PS6 for laser 
    ; PS7 for the Left spectrometer based on S0, timed with calorimeter
    ; PS8 for pulser 
    ps1=1000000,ps2=1000000,ps3=100,ps4=200,ps5=1,ps6=20,ps7=65000,ps8=1024
     
    Left Arm Q1 power supply current : 2999.64
    Left Arm Q1 momentum : 3.98712
    Left Arm Q1 gauss meter : 0.25411
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1716.97
    Left Arm Q2 momentum : 3.9874
    Left Arm Q2 gauss meter : -0.9028
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1494.71
    Left Arm D1 momentum : 3.987
    Left Arm D1 NMR : 1.47708
    Left Arm Q3 power supply current : 1587.3
    Left Arm Q3 momentum : 3.98699
    Left Arm Q3 gauss meter : 0.7939
    Left Arm Q3 power supply polarity : 0
    Left Arm Top VDC Current : 0.732422
    Left Arm Bottom VDC Current : -1.17188
    Average current of the two cavities : 0.0321618
    Current on Unser monitor : 7.9622
    Current on Upstream bcm : 0.0360293
    Current on Downstream bcm : 0.0282943
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 9.98854
    Tiefenbach Hall A energy : 4615.54
    Tiefenbach Hall C energy : 5751.95
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : 4625.04
    MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.08
    MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 192.932
    MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 1.15418e+06
    Arc1 dp/p : 3.74893e-05
    Arc2 dp/p : -0.00183291
    Left Arm Arm Collimator : 0.0655762
    HacL_HPE1313A:0_Ch58 : -0.174316
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : 0.0610352
    HacL_alignROLL : 0.399476
    HacL_alignPITCH : -0.108447
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 15.5
    Left Arm Angle Vernier : 10
    Left Arm Scattering Angle : 15.3786
    IPM1C12.XPOS : -4.76887
    IPM1C12.YPOS : 1.3797
    IPM1H04A.XPOS : -0.00578244
    IPM1H04A.YPOS : 1.4306
    IPM1H04B.XPOS : -2.05026
    IPM1H04B.YPOS : 1.49628
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Beam Half-wave plate (off=out) :
    Target OTR x-position : -1.58507
    Target OTR y-position : 1.56678
    Target OTR x-width : 0.490562
    Target OTR y-width : 0.478358
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -0.735413
    Arc OTR y-position : 0.179918
    Arc OTR x-width : 4.41307
    Arc OTR y-width : 3.56156
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 500
    Current Readback : 500.382