• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:07:58 on January 28, 2002

    Entry number 81073

    keyword=End_of_Run_1801
    ****************************
     Run Number: 1801
     End of Run Comment:
    Run_type=optics,beam_energy=4.6155,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=oprics (C), 4E,  magnet off, raster off,  veto on, 5microAmp, energy measurement,daq_mode=coincidence,leftarm_p=3.137,leftarm_theta=24.951,photonarm_D=7.9,photonarm_angle=42,photonarm_p=3.742,target_name=optics,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=10000   ps2=100000   ps3=1   ps4=50   ps5=1   ps6=20   ps7=65000   ps8=1024   
    
    EVENTS[0]: 136993       [+]: 67342        [-]: 67090        
    TIME  [0]: 85.170 mins  [+]: 41.796 mins  [-]: 41.796 mins  
    LIVE  [0]:  97.25%      [+]:  97.15%      [-]:  97.34%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.1/542.2 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :25.9/25.9 Hz   T4[0] : 0.4/22.0 Hz   T5[0] : 0.1/0.1  Hz   T6[0] : 0.0/1.0  Hz   T7[0] : 0.0/376.8 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 0.1/541.4 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :26.0/26.0 Hz   T4[+] : 0.4/22.2 Hz   T5[+] : 0.1/0.1  Hz   T6[+] : 0.0/1.0  Hz   T7[+] : 0.0/377.8 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 0.1/541.9 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :25.9/25.9 Hz   T4[-] : 0.4/21.8 Hz   T5[-] : 0.1/0.1  Hz   T6[-] : 0.0/1.0  Hz   T7[-] : 0.0/376.1 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    277/2770752  T2[0] :      0/231      T3[0] : 132577/132577   T4[0] :   2248/112424   T5[0] :    383/383      T6[0] :    247/4946     T7[0] :     29/1925313  T8[0] :   5110/5232829  
    T1[+] :    135/1357781  T2[+] :      0/102      T3[+] :  65244/65244    T4[+] :   1113/55666    T5[+] :    183/183      T6[+] :    122/2441     T7[+] :     14/947318   T8[+] :   2507/2567924  
    T1[-] :    135/1359005  T2[-] :      0/122      T3[-] :  64864/64864    T4[-] :   1093/54682    T5[-] :    189/189      T6[-] :    121/2431     T7[-] :     14/943212   T8[-] :   2507/2567943  
    
    AVERAGE CURRENT
    BCM x1 : 3.3007 uA  BCM x3 : 3.2961 uA  BCM x10: 3.3028 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :   -490.4 ppm     BCM u3 :     -523 ppm     BCM u10:   -539.5 ppm     
    BCM d1 :   -476.8 ppm     BCM d3 :   -514.4 ppm     BCM d10:   -539.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01658        BCM u3 [0]:0.01645        BCM u10[0]:0.01653        
    BCM u1 [+]:0.008134       BCM u3 [+]:0.008075       BCM u10[+]:0.008112       
    BCM u1 [-]:0.008142       BCM u3 [-]:0.008083       BCM u10[-]:0.008121       
    
    BCM d1 [0]:0.01716        BCM d3 [0]:0.01723        BCM d10[0]:0.01723        
    BCM d1 [+]:0.008419       BCM d3 [+]:0.008458       BCM d10[+]:0.008454       
    BCM d1 [-]:0.008427       BCM d3 [-]:0.008466       BCM d10[-]:0.008463       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1801 at Mon Jan 28 04:07:28 EST 2002
    Left Arm D1 momentum : 3.137
    Left Arm arm angle : 24.9507
    Tiefenbach Hall A energy : 4615.57
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 3.80859
    Left Arm Bottom VDC Current : 1.80664
    Left Arm Q1 power supply current : 2360.23
    Left Arm Q1 momentum : 3.13721
    Left Arm Q1 gauss meter : 0.20003
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1350.66
    Left Arm Q2 momentum : 3.13669
    Left Arm Q2 gauss meter : -0.7109
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1102.06
    Left Arm D1 momentum : 3.137
    Left Arm D1 NMR : 1.16168
    Left Arm Q3 power supply current : 1248.82
    Left Arm Q3 momentum : 3.13687
    Left Arm Q3 gauss meter : 0.6251
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 6.34911
    Current on Unser monitor : 13.0093
    Current on Upstream bcm : 6.33989
    Current on Downstream bcm : 6.41968
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 6.44395
    MBSY1c Hall A Beam energy :
    MBSY1c magnet current (amp) : 192.932
    MBSY1c Bdl : 1.15418e+06
    MBSY3c Hall C Beam energy : 5770.08
    Tiefenbach Hall A energy : 4615.57
    Tiefenbach Hall C energy : 5755.14
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.0161906
    IPM1H04A.XPOS : 1.16265
    IPM1H04A.YPOS : 0.250119
    IPM1H04B.XPOS : -0.223498
    IPM1H04B.YPOS : 0.36053
    Left Arm Arm Collimator : 0.0656738
    HacL_HPE1313A:0_Ch58 : -0.119629
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.186035
    HacL_alignROLL : 0.166074
    HacL_alignPITCH :
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.0657227
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag :
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.461353
    Arc OTR y-position : -0.567004
    Arc OTR x-width : 4.19153
    Arc OTR y-width : 3.63807
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286