• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 11:40:47 on January 30, 2002

    Entry number 81313

    keyword=Start_Run_1886,Run_type=production,beam_energy=4.6155,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=junk run, ignore,daq_mode=coincidence,leftarm_p=2.970,leftarm_theta=28.160,photonarm_D=10.1,photonarm_angle=35.0,photonarm_p=,target_name=LH2 no R,target_type=15LH2
    Beginning-of-run EPICS data for Run Number 1886 at Wed Jan 30 11:40:35 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the calorimeter singles based on summers
    ; PS2 for the cosmic trigger for calorimeter 
    ; PS3 for the Left spectrometer based on T3 - S1+S2
    ; PS4 for the Left spectrometer redundant trigger S1+S2 or
    ;                        based on S1+S0 or S2+S0
    ; PS5 for Coinc. trigger based on S0 and Calo
    ; PS6 for laser 
    ; PS7 for the Left spectrometer based on S0, timed with calorimeter
    ; PS8 for pulser 
    ps1=2700,ps2=100000,ps3=5,ps4=13,ps5=1,ps6=1,ps7=65000,ps8=1024
     
    Left Arm Q1 power supply current : 2234.65
    Left Arm Q1 momentum : 2.97029
    Left Arm Q1 gauss meter : 0.18944
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1278.71
    Left Arm Q2 momentum : 2.96959
    Left Arm Q2 gauss meter : -0.6733
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1038.15
    Left Arm D1 momentum : 2.97
    Left Arm D1 NMR : 1.09971
    Left Arm Q3 power supply current : 1182.39
    Left Arm Q3 momentum : 2.96995
    Left Arm Q3 gauss meter : 0.592
    Left Arm Q3 power supply polarity : 0
    Left Arm Top VDC Current : 2.00195
    Left Arm Bottom VDC Current : 0.390625
    Average current of the two cavities : 0.0310802
    Current on Unser monitor : 6.86065
    Current on Upstream bcm : 0.0341696
    Current on Downstream bcm : 0.0279406
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 4615.51
    Tiefenbach Hall C energy : 5752.31
    Delta(E)/E width (MV_AI_DXWID) : 1.64181
    MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 4625.04
    MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.08
    MBSY1c magnet current (amp) : 192.932
    MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1.15418e+06
    Arc1 dp/p : 7.88206e-05
    Arc2 dp/p : -0.00181354
    Left Arm Arm Collimator : 0.868652
    HacL_HPE1313A:0_Ch58 : -0.150391
    HacL_HPE1313A:0_Ch55 : 23.3398
    HacL_HPE1313A:0_Ch54 : -0.185059
    HacL_alignROLL : 0.169904
    HacL_alignPITCH : -0.11003
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 28
    Left Arm Angle Vernier : 58.9
    Left Arm Scattering Angle : 28.1605
    IPM1C12.XPOS : -0.00239089
    IPM1C12.YPOS : 0.0455279
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Beam Half-wave plate (off=out) :
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : 0.486011
    Arc OTR y-position : -0.56493
    Arc OTR x-width : 4.18796
    Arc OTR y-width : 3.62786
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 500
    Current Readback : 500.382