• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 00:14:48 on February 1, 2002

    Entry number 81419

    keyword=End_of_Run_1931
    ****************************
     Run Number: 1931
     End of Run Comment:
    Run_type=epcalib,beam_energy=4.6155,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=ep end pt, magnet off, run raster on, veto off, 4A,daq_mode=coincidence,leftarm_p=1.943,leftarm_theta=40.969,photonarm_D=18.0,photonarm_angle=22.0,photonarm_p=,target_name=LH2,target_type=15LH2
     
    
    PRESCALE FACTORS:ps1=1000   ps2=100000   ps3=20   ps4=10   ps5=1   ps6=1   ps7=200   ps8=100   
    
    EVENTS[0]: 123776       [+]: 60782        [-]: 60762        
    TIME  [0]: 8.031 mins  [+]: 3.941 mins  [-]: 3.941 mins  
    LIVE  [0]:  88.32%      [+]:  88.40%      [-]:  88.28%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :16.4/16441.1 Hz   T2[0] : 0.0/0.8  Hz   T3[0] :15.6/311.7 Hz   T4[0] :11.1/111.2 Hz   T5[0] :226.6/226.6 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 9.9/1981.0 Hz   T8[0] :10.2/1024.0 Hz   
    T1[+] :16.4/16437.1 Hz   T2[+] : 0.0/0.8  Hz   T3[+] :15.6/311.5 Hz   T4[+] :11.1/110.6 Hz   T5[+] :226.6/226.6 Hz   T6[+] : 1.0/1.0  Hz   T7[+] : 9.9/1978.5 Hz   T8[+] :10.2/1024.0 Hz   
    T1[-] :16.4/16420.5 Hz   T2[-] : 0.0/0.7  Hz   T3[-] :15.6/312.2 Hz   T4[-] :11.2/112.0 Hz   T5[-] :226.7/226.7 Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 9.9/1983.9 Hz   T8[-] :10.2/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   7922/7922737  T2[0] :      0/368      T3[0] :   7511/150226   T4[0] :   5359/53590    T5[0] : 109176/109176   T6[0] :    467/467      T7[0] :   4773/954632   T8[0] :   4934/493450   
    T1[+] :   3886/3886320  T2[+] :      0/193      T3[+] :   3682/73643    T4[+] :   2616/26161    T5[+] :  53587/53587    T6[+] :    227/227      T7[+] :   2338/467798   T8[+] :   2421/242110   
    T1[-] :   3882/3882676  T2[-] :      0/172      T3[-] :   3691/73821    T4[-] :   2647/26479    T5[-] :  53612/53612    T6[-] :    231/231      T7[-] :   2345/469109   T8[-] :   2421/242128   
    
    AVERAGE CURRENT
    BCM x1 : 17.3769uA  BCM x3 : 17.4089uA  BCM x10: 17.3693uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    103.5 ppm     BCM u3 :     92.4 ppm     BCM u10:    90.73 ppm     
    BCM d1 :    105.9 ppm     BCM d3 :    94.95 ppm     BCM d10:    89.38 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.008173       BCM u3 [0]:0.008198       BCM u10[0]:0.008214       
    BCM u1 [+]:0.00401        BCM u3 [+]:0.004023       BCM u10[+]:0.00403        
    BCM u1 [-]:0.00401        BCM u3 [-]:0.004022       BCM u10[-]:0.00403        
    
    BCM d1 [0]:0.008574       BCM d3 [0]:0.00858        BCM d10[0]:0.008526       
    BCM d1 [+]:0.004207       BCM d3 [+]:0.00421        BCM d10[+]:0.004184       
    BCM d1 [-]:0.004207       BCM d3 [-]:0.004209       BCM d10[-]:0.004183       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 1931 at Fri Feb 1 00:14:40 EST 2002
    Left Arm D1 momentum : 1.943
    Left Arm arm angle : 40.9685
    Tiefenbach Hall A energy : 4615.46
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 3.90625
    Left Arm Bottom VDC Current : -0.146484
    Left Arm Q1 power supply current : 1461.78
    Left Arm Q1 momentum : 1.94299
    Left Arm Q1 gauss meter : 0.12431
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 836.658
    Left Arm Q2 momentum : 1.943
    Left Arm Q2 gauss meter : -0.4409
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 657.129
    Left Arm D1 momentum : 1.943
    Left Arm D1 NMR : 0.718991
    Left Arm Q3 power supply current : 772.987
    Left Arm Q3 momentum : 1.9416
    Left Arm Q3 gauss meter : 0.3872
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 34.7965
    Current on Unser monitor : 41.5898
    Current on Upstream bcm : 34.5059
    Current on Downstream bcm : 35.0871
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 35.6002
    MBSY1c Hall A Beam energy : 4625.06
    MBSY1c magnet current (amp) : 192.933
    MBSY1c Bdl : 1.15419e+06
    MBSY3c Hall C Beam energy : 5770.08
    Tiefenbach Hall A energy : 4615.46
    Tiefenbach Hall C energy : 5753.37
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.0489851
    IPM1H04A.XPOS : -0.541581
    IPM1H04A.YPOS : 1.63719
    IPM1H04B.XPOS : -2.03396
    IPM1H04B.YPOS : 1.55991
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.21875
    HacL_HPE1313A:0_Ch55 : 23.2422
    HacL_HPE1313A:0_Ch54 : -0.264648
    HacL_alignROLL : 0.0978367
    HacL_alignPITCH : -0.0492749
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Target OTR x-position : -1.5652
    Target OTR y-position : 1.9145
    Target OTR x-width : 0.805086
    Target OTR y-width : 0.821073
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.732684
    Arc OTR y-position : 0.245191
    Arc OTR x-width : 4.40852
    Arc OTR y-width : 3.55104
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286