Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 07:08:03 on February 1, 2002
Entry number 81450
keyword=Start_Run_1946,Run_type=production,beam_energy=4.6155,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=RCS offendpt, magnet on, raster on, veto on, 4A, 15 uA,daq_mode=coincidence,leftarm_p=1.789,leftarm_theta=42.580,photonarm_D=18.0,photonarm_angle=22.0,photonarm_p=,target_name=LH2-R,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 1946 at Fri Feb 1 07:07:49 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=600,ps2=100000,ps3=6,ps4=8,ps5=1,ps6=1,ps7=90,ps8=100
Left Arm Q1 power supply current : 1345.85
Left Arm Q1 momentum : 1.78891
Left Arm Q1 gauss meter : 0.11458
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 770.109
Left Arm Q2 momentum : 1.78846
Left Arm Q2 gauss meter : -0.4061
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 602.262
Left Arm D1 momentum :
Left Arm D1 NMR : 0.662037
Left Arm Q3 power supply current : 712.176
Left Arm Q3 momentum : 1.78885
Left Arm Q3 gauss meter : 0.3567
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 2.97852
Left Arm Bottom VDC Current : 3.02734
Average current of the two cavities : 3.14664
Current on Unser monitor : 9.5757
Current on Upstream bcm : 3.11462
Current on Downstream bcm : 3.20804
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 3.42296
Tiefenbach Hall A energy : 4615.55
Tiefenbach Hall C energy : 5752.67
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 4625.06
MBSY3c Hall C Beam energy : 5770.08
MBSY1c magnet current (amp) : 192.933
MBSY1c Bdl : 1.15419e+06
Arc1 dp/p : 7.5994e-05
Arc2 dp/p : -0.00177548
Left Arm Arm Collimator : 0.868555
HacL_HPE1313A:0_Ch58 : -0.229492
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.317871
HacL_alignROLL : 0.0496932
HacL_alignPITCH : -0.039234
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 42.5
Left Arm Angle Vernier : 44.9
Left Arm Scattering Angle : 42.5798
IPM1C12.XPOS : -0.00999101
IPM1C12.YPOS : 0.0558858
IPM1H04A.XPOS : -0.556114
IPM1H04A.YPOS : 1.69281
IPM1H04B.XPOS : -1.98056
IPM1H04B.YPOS : 1.59706
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -1.31568
Target OTR y-position : 2.15341
Target OTR x-width : 0.799874
Target OTR y-width : 0.853168
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -0.722081
Arc OTR y-position : 0.231572
Arc OTR x-width : 4.41873
Arc OTR y-width : 3.56205
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 600
Current Readback : 600.407