User name a-onl
Log entry time 09:26:18 on February 2, 2002
Entry number 81523
keyword=Start_Run_1973,Run_type=cosmics,beam_energy=4.6155,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=cosmic run to check FPP,daq_mode=coincidence,leftarm_p=3.8,leftarm_theta=14.573,photonarm_D=18.0,photonarm_angle=90.0,photonarm_p=,target_name=cosmic,target_type=Carbon Foil
Beginning-of-run EPICS data for Run Number 1973 at Sat Feb 2 09:26:03 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=2000,ps2=100000,ps3=1,ps4=35,ps5=1,ps6=1,ps7=320,ps8=100
Left Arm Q1 power supply current : 3009.37
Left Arm Q1 momentum : 4.00006
Left Arm Q1 gauss meter : -0.2542
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1722.33
Left Arm Q2 momentum : 3.99984
Left Arm Q2 gauss meter : 0.9062
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1502.98
Left Arm D1 momentum : 4
Left Arm D1 NMR : 1.4819
Left Arm Q3 power supply current : 1592.47
Left Arm Q3 momentum : 3.99998
Left Arm Q3 gauss meter : -0.7966
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : -2.24609
Left Arm Bottom VDC Current : 0.830078
Average current of the two cavities : 0.0297948
Current on Unser monitor : 6.28718
Current on Upstream bcm : 0.0334766
Current on Downstream bcm : 0.0261131
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5754.93
Tiefenbach Hall C energy : 5752.49
Delta(E)/E width (MV_AI_DXWID) :
MBSY1c Hall A Beam energy : 5774.99
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.08
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 0.0377197
MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1.44116e+06
Arc1 dp/p : 6.87525e-05
Arc2 dp/p : -0.00156559
Left Arm Arm Collimator : 0.868555
HacL_HPE1313A:0_Ch58 : -0.108398
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.0966797
HacL_alignROLL : 0.248819
HacL_alignPITCH : -0.148358
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : 65.8
Left Arm Scattering Angle : 19.7003
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 0.398728
Arc OTR y-position : -0.565418
Arc OTR x-width : 4.19982
Arc OTR y-width : 3.63793
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.208286