User name a-onl
Log entry time 14:22:03 on February 2, 2002
Entry number 81553
keyword=Start_Run_1984,Run_type=optics,beam_energy=5.751,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=acceptance scan,daq_mode=coincidence,leftarm_p=4.0,leftarm_theta=14.573,photonarm_D=18.0,photonarm_angle=90.0,photonarm_p=,target_name=optics,target_type=Carbon Foil
Beginning-of-run EPICS data for Run Number 1984 at Sat Feb 2 14:21:26 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=2000,ps2=100000,ps3=1,ps4=35,ps5=1,ps6=1,ps7=65000,ps8=100
Left Arm Q1 power supply current : 3009.3
Left Arm Q1 momentum : 3.99997
Left Arm Q1 gauss meter : -0.2542
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1722.52
Left Arm Q2 momentum : 4.00029
Left Arm Q2 gauss meter : 0.9062
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1502.98
Left Arm D1 momentum : 3.99999
Left Arm D1 NMR : 1.4819
Left Arm Q3 power supply current : 1592.49
Left Arm Q3 momentum : 4.00004
Left Arm Q3 gauss meter : -0.79668
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : 3.90625
Left Arm Bottom VDC Current : -0.0976562
Average current of the two cavities : 20.3596
Current on Unser monitor : 26.8408
Current on Upstream bcm : 19.9924
Current on Downstream bcm : 20.5309
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 20.9099
Tiefenbach Hall A energy : 5752.57
Tiefenbach Hall C energy : 5753.57
Delta(E)/E width (MV_AI_DXWID) : 2.54455
MBSY1c Hall A Beam energy : 5762.97
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.08
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 240.916
MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 1.43816e+06
Arc1 dp/p : 6.73272e-05
Arc2 dp/p : -0.00157987
Left Arm Arm Collimator : 0.868506
HacL_HPE1313A:0_Ch58 : -0.108398
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.0981445
HacL_alignROLL : 0.248302
HacL_alignPITCH : -0.148283
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 19.5
Left Arm Angle Vernier : 65.8
Left Arm Scattering Angle : 19.7003
IPM1C12.XPOS : -1.15415
IPM1C12.YPOS : 0.0246996
IPM1H04A.XPOS : 0.981462
IPM1H04A.YPOS : 0.735168
IPM1H04B.XPOS : -2.03838
IPM1H04B.YPOS : 1.64749
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -1.49788
Target OTR y-position : 1.97463
Target OTR x-width : 0.793688
Target OTR y-width : 0.796061
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : 0.413064
Arc OTR y-position : -0.556108
Arc OTR x-width : 4.18948
Arc OTR y-width : 3.64669
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.208286