Log entry time 19:30:13 on February 2, 2002
Entry number 81586
keyword=Start_Run_1997,Run_type=production,beam_energy=5.751,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=acceptance scan,daq_mode=coincidence,leftarm_p=4.0,leftarm_theta=23.428,photonarm_D=18.0,photonarm_angle=90.0,photonarm_p=,target_name=LH2norad,target_type=15LH2
Beginning-of-run EPICS data for Run Number 1997 at Sat Feb 2 19:29:57 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=1150000,ps2=100000,ps3=1,ps4=35,ps5=10000,ps6=1,ps7=65000,ps8=1024
Left Arm Q1 power supply current : 3009.41
Left Arm Q1 momentum : 4.0001
Left Arm Q1 gauss meter : -0.25419
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1722.48
Left Arm Q2 momentum : 4.00018
Left Arm Q2 gauss meter : 0.9062
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1502.97
Left Arm D1 momentum : 4
Left Arm D1 NMR : 1.4819
Left Arm Q3 power supply current : 1592.46
Left Arm Q3 momentum : 3.99997
Left Arm Q3 gauss meter : -0.7966
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : -2.88086
Left Arm Bottom VDC Current : 1.26953
Average current of the two cavities : 7.63209
Current on Unser monitor : 14.3251
Current on Upstream bcm : 8.16985
Current on Downstream bcm : 7.09433
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 8.34165
Tiefenbach Hall A energy : 5750.97
Tiefenbach Hall C energy : 5751.84
Delta(E)/E width (MV_AI_DXWID) : 2.62857
MBSY1c Hall A Beam energy : 5762.97
MBSY3c Hall C Beam energy : 5770.08
MBSY1c magnet current (amp) : 240.916
MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 1.43816e+06
Arc1 dp/p : 7.36159e-05
Arc2 dp/p : -0.00192543
Left Arm Arm Collimator : 0.868506
HacL_HPE1313A:0_Ch58 : -0.118652
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.208496
HacL_alignROLL : 0.148237
HacL_alignPITCH : -0.139154
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 23.5
Left Arm Angle Vernier : 18.5
Left Arm Scattering Angle : 23.4276
IPM1C12.XPOS : 0.0414841
IPM1C12.YPOS : 0.0841357
IPM1H04A.XPOS : 0.897415
IPM1H04A.YPOS : 0.673077
IPM1H04B.XPOS : -2.09048
IPM1H04B.YPOS : 1.49924
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -1.4972
Target OTR y-position : 1.80511
Target OTR x-width : 0.775574
Target OTR y-width : 0.789569
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : 0.450074
Arc OTR y-position : -0.5558
Arc OTR x-width : 4.19565
Arc OTR y-width : 3.62788
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.208286