Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 01:22:46 on February 4, 2002
Entry number 81681
keyword=Start_Run_2030,Run_type=cosmics,beam_energy=5.784,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Cosmic ray test,daq_mode=coincidence,leftarm_p=3.50,leftarm_theta=38.47,photonarm_D=18.0,photonarm_angle=20.0,photonarm_p=2220,target_name=LH2norad,target_type=15LH2
Beginning-of-run EPICS data for Run Number 2030 at Mon Feb 4 01:22:31 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=3000,ps2=1,ps3=1,ps4=10,ps5=1,ps6=1,ps7=300,ps8=1024
Left Arm Q1 power supply current : 1738.77
Left Arm Q1 momentum : 2.31126
Left Arm Q1 gauss meter : 0.14752
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current :
Left Arm Q2 momentum : 2.31054
Left Arm Q2 gauss meter : -0.5241
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 791.626
Left Arm D1 momentum : 2.31099
Left Arm D1 NMR : 0.855175
Left Arm Q3 power supply current : 920.039
Left Arm Q3 momentum : 2.31097
Left Arm Q3 gauss meter : 0.4606
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 3.95508
Left Arm Bottom VDC Current : 1.26953
Average current of the two cavities : 0.0309815
Current on Unser monitor : 7.54726
Current on Upstream bcm : 0.0340565
Current on Downstream bcm : 0.0279065
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5750.96
Tiefenbach Hall C energy : 5753.64
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 5762.97
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.08
MBSY1c magnet current (amp) : 0.0377197
MBSY1c Bdl : 1.43816e+06
Arc1 dp/p : 6.76606e-05
Arc2 dp/p : -0.00135756
Left Arm Arm Collimator : 0.868457
HacL_HPE1313A:0_Ch58 : -0.165039
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.267578
HacL_alignROLL : 0.0953112
HacL_alignPITCH : -0.0974491
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 38.5
Left Arm Angle Vernier : 25.9
Left Arm Scattering Angle : 38.4703
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -0.767247
Arc OTR y-position : 0.302764
Arc OTR x-width : 4.40535
Arc OTR y-width : 3.55086
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.272374