User name a-onl
Log entry time 16:43:32 on February 4, 2002
Entry number 81759
keyword=Start_Run_2063,Run_type=cosmics,beam_energy=5.766,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=OPTICS HRSL,daq_mode=coincidence,leftarm_p=3.002,leftarm_theta=31.25,photonarm_D=14.5,photonarm_angle=26.0,photonarm_p=1870,target_name=OPTICS,target_type=Carbon Foil
Beginning-of-run EPICS data for Run Number 2063 at Mon Feb 4 16:43:19 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=5000,ps2=100000,ps3=1,ps4=50,ps5=1,ps6=1,ps7=30000,ps8=1024
Left Arm Q1 power supply current : 2258.48
Left Arm Q1 momentum : 3.00197
Left Arm Q1 gauss meter : 0.19138
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1292.82
Left Arm Q2 momentum : 3.00237
Left Arm Q2 gauss meter : -0.6805
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1051.17
Left Arm D1 momentum : 3.002
Left Arm D1 NMR : 1.11158
Left Arm Q3 power supply current : 1195.13
Left Arm Q3 momentum : 3.00194
Left Arm Q3 gauss meter : 0.5984
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : -2.92969
Left Arm Bottom VDC Current : 3.75977
Average current of the two cavities : 0.0299638
Current on Unser monitor : 7.20847
Current on Upstream bcm : 0.0331377
Current on Downstream bcm : 0.02679
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5754.14
Tiefenbach Hall C energy : 5754.42
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5766.18
MBSY3c Hall C Beam energy : 5770.08
MBSY1c magnet current (amp) : 241.051
MBSY1c Bdl : 1.43896e+06
Arc1 dp/p : 6.62144e-05
Arc2 dp/p : -0.00137354
Left Arm Arm Collimator : 0.868457
HacL_HPE1313A:0_Ch58 : -0.149902
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.196777
HacL_alignROLL : 0.160179
HacL_alignPITCH :
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 31
Left Arm Angle Vernier : 74.4
Left Arm Scattering Angle : 31.2498
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -0.742845
Arc OTR y-position : 0.263918
Arc OTR x-width : 4.41235
Arc OTR y-width : 3.55134
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.192264