    Log entry time 12:38:31 on February 5, 2002

    Entry number 81855

    keyword=Start_Run_2108,Run_type=cosmics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=Cosmic, magnet OFF, veto ON,daq_mode=coincidence,leftarm_p=2.772,leftarm_theta=32.66,photonarm_D=14.5,photonarm_angle=26.0,photonarm_p=1000,target_name=none,target_type=Empty
    Beginning-of-run EPICS data for Run Number 2108 at Tue Feb 5 12:38:18 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the calorimeter singles based on summers
    ; PS2 for the cosmic trigger for calorimeter 
    ; PS3 for the Left spectrometer based on T3 - S1+S2
    ; PS4 for the Left spectrometer redundant trigger S1+S2 or
    ;                        based on S1+S0 or S2+S0
    ; PS5 for Coinc. trigger based on S0 and Calo
    ; PS6 for laser 
    ; PS7 for the Left spectrometer based on S0, timed with calorimeter
    ; PS8 for pulser 
    ps1=100,ps2=1,ps3=1,ps4=50,ps5=1,ps6=1,ps7=40000,ps8=1024
     
    Left Arm Q1 power supply current : 2085.65
    Left Arm Q1 momentum : 2.77225
    Left Arm Q1 gauss meter : 0.17681
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1193.57
    Left Arm Q2 momentum : 2.77187
    Left Arm Q2 gauss meter : -0.6285
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 963.085
    Left Arm D1 momentum : 2.772
    Left Arm D1 NMR : 1.02624
    Left Arm Q3 power supply current : 1103.51
    Left Arm Q3 momentum : 2.77182
    Left Arm Q3 gauss meter : 0.5524
    Left Arm Q3 power supply polarity : 0
    Left Arm Top VDC Current : -1.2207
    Left Arm Bottom VDC Current : -1.17188
    Average current of the two cavities : 0.0367127
    Current on Unser monitor : 6.73854
    Current on Upstream bcm : 0.0415447
    Current on Downstream bcm : 0.0318808
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 5754.76
    Tiefenbach Hall C energy : 5753.82
    Delta(E)/E width (MV_AI_DXWID) : 0.89133
    MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5766.18
    MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.08
    MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 241.051
    MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1.43896e+06
    Arc1 dp/p : 8.16913e-05
    Arc2 dp/p : -0.00156875
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.148926
    HacL_HPE1313A:0_Ch55 : 23.6328
    HacL_HPE1313A:0_Ch54 : -0.214355
    HacL_alignROLL : 0.143392
    HacL_alignPITCH : -0.111784
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 32.5
    Left Arm Angle Vernier : 59.5
    Left Arm Scattering Angle : 32.6639
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Beam Half-wave plate (off=out) :
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : 0.400821
    Arc OTR y-position : -0.575482
    Arc OTR x-width : 4.21328
    Arc OTR y-width : 3.63097
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286