• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 22:02:51 on February 6, 2002

    Entry number 82028

    keyword=End_of_Run_2181
    ****************************
     Run Number: 2181
     End of Run Comment:
    Run_type=optics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Optics 5E(g), beam current 25 uA, veto OFF, RCS magnet OFF,daq_mode=coincidence,leftarm_p=3.494,leftarm_theta=25.830,photonarm_D=9.5,photonarm_angle=34.0,photonarm_p=1100,target_name=Optics,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=35000   ps2=100000   ps3=1   ps4=34   ps5=1   ps6=1   ps7=650   ps8=1024   
    
    EVENTS[0]: 103884       [+]: 50666        [-]: 51387        
    TIME  [0]: 21.464 mins  [+]: 10.531 mins  [-]: 10.533 mins  
    LIVE  [0]:  97.42%      [+]:  97.40%      [-]:  97.45%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.5/18776.5 Hz   T2[0] : 0.0/0.7  Hz   T3[0] :71.3/71.3 Hz   T4[0] : 1.9/65.9 Hz   T5[0] : 3.8/3.8  Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 3.3/2127.3 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 0.5/18678.9 Hz   T2[+] : 0.0/0.7  Hz   T3[+] :70.9/70.9 Hz   T4[+] : 1.9/66.0 Hz   T5[+] : 3.7/3.7  Hz   T6[+] : 0.9/0.9  Hz   T7[+] : 3.3/2121.7 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 0.5/18838.6 Hz   T2[-] : 0.0/0.8  Hz   T3[-] :71.9/71.9 Hz   T4[-] : 1.9/65.9 Hz   T5[-] : 3.8/3.8  Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 3.3/2133.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    690/24181418  T2[0] :      0/961      T3[0] :  91835/91835    T4[0] :   2497/84922    T5[0] :   4864/4864     T6[0] :   1247/1247     T7[0] :   4214/2739628  T8[0] :   1287/1318765  
    T1[+] :    337/11803032  T2[+] :      0/457      T3[+] :  44796/44796    T4[+] :   1226/41706    T5[+] :   2367/2367     T6[+] :    597/597      T7[+] :   2062/1340661  T8[+] :    631/647055   
    T1[-] :    340/11905993  T2[-] :      0/480      T3[-] :  45439/45439    T4[-] :   1225/41673    T5[-] :   2412/2412     T6[-] :    611/611      T7[-] :   2074/1348649  T8[-] :    632/647169   
    
    AVERAGE CURRENT
    BCM x1 : 32.9569uA  BCM x3 : 33.0214uA  BCM x10: 32.9858uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -3610 ppm     BCM u3 :    -3521 ppm     BCM u10:    -3563 ppm     
    BCM d1 :    -3619 ppm     BCM d3 :    -3457 ppm     BCM d10:    -3491 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.04138        BCM u3 [0]:0.04153        BCM u10[0]:0.0416         
    BCM u1 [+]:0.02023        BCM u3 [+]:0.02031        BCM u10[+]:0.02034        
    BCM u1 [-]:0.02038        BCM u3 [-]:0.02046        BCM u10[-]:0.02049        
    
    BCM d1 [0]:0.04351        BCM d3 [0]:0.04352        BCM d10[0]:0.04337        
    BCM d1 [+]:0.02127        BCM d3 [+]:0.02128        BCM d10[+]:0.02121        
    BCM d1 [-]:0.02143        BCM d3 [-]:0.02143        BCM d10[-]:0.02136        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2181 at Wed Feb 6 22:02:42 EST 2002
    Left Arm D1 momentum : 3.494
    Left Arm arm angle : 25.8302
    Tiefenbach Hall A energy : 5754.18
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.7832
    Left Arm Bottom VDC Current : -2.00195
    Left Arm Q1 power supply current : 2628.47
    Left Arm Q1 momentum : 3.49376
    Left Arm Q1 gauss meter : 0.22266
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1504.63
    Left Arm Q2 momentum : 3.49426
    Left Arm Q2 gauss meter : -0.7914
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1249.67
    Left Arm D1 momentum : 3.494
    Left Arm D1 NMR : 1.29414
    Left Arm Q3 power supply current : 1391.01
    Left Arm Q3 momentum : 3.49397
    Left Arm Q3 gauss meter : 0.6959
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0304932
    Current on Unser monitor : 7.46354
    Current on Upstream bcm : 0.0339821
    Current on Downstream bcm : 0.0270043
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5766.17
    MBSY1c magnet current (amp) : 241.051
    MBSY1c Bdl : 1.43895e+06
    MBSY3c Hall C Beam energy : 5770.09
    Tiefenbach Hall A energy : 5754.18
    Tiefenbach Hall C energy : 5753.75
    Delta(E)/E width (MV_AI_DXWID) : 0.0328834
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.868457
    HacL_HPE1313A:0_Ch58 : -0.129395
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.194336
    HacL_alignROLL : 0.162236
    HacL_alignPITCH : -0.129111
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : -0.734229
    Arc OTR y-position : 0.267811
    Arc OTR x-width : 4.4144
    Arc OTR y-width : 3.55152
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.272374