Log entry time 13:04:10 on February 7, 2002
Entry number 82082
keyword=Start_Run_2209,Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=LH2 5G(e), beam current 30 uA, veto OFF, RCS magnet ON, 30 uA, threshold is 1000 MeV,daq_mode=coincidence,leftarm_p=3.992,leftarm_theta=21.59,photonarm_D=8.1,photonarm_angle=41.0,photonarm_p=1000,target_name=LH2 Rad,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 2209 at Thu Feb 7 13:03:54 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=32500,ps2=100000,ps3=35,ps4=43,ps5=1,ps6=1,ps7=890,ps8=1024
Left Arm Q1 power supply current : 3003.28
Left Arm Q1 momentum : 3.99196
Left Arm Q1 gauss meter : 0.25441
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1718.82
Left Arm Q2 momentum : 3.9917
Left Arm Q2 gauss meter : -0.9041
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1497.62
Left Arm D1 momentum : 3.99201
Left Arm D1 NMR : 1.47894
Left Arm Q3 power supply current : 1589.25
Left Arm Q3 momentum : 3.99191
Left Arm Q3 gauss meter : 0.7949
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 2.44141
Left Arm Bottom VDC Current : -2.09961
Average current of the two cavities : 0.033448
Current on Unser monitor : 7.1422
Current on Upstream bcm : 0.037479
Current on Downstream bcm : 0.029417
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5754.11
Tiefenbach Hall C energy : 5753.78
Delta(E)/E width (MV_AI_DXWID) : 0.309648
MBSY1c Hall A Beam energy : 5766.17
MBSY3c Hall C Beam energy : 5770.09
MBSY1c magnet current (amp) : 241.051
MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 1.43895e+06
Arc1 dp/p : 6.61678e-05
Arc2 dp/p : -0.00146569
Left Arm Arm Collimator : 0.868457
HacL_HPE1313A:0_Ch58 : -0.114258
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.117676
HacL_alignROLL :
HacL_alignPITCH : -0.143521
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 22
Left Arm Angle Vernier : -40.1
Left Arm Scattering Angle : 21.5899
IPM1C12.XPOS : 2.11733
IPM1C12.YPOS : 1.67976
IPM1H04A.XPOS : 0.796662
IPM1H04A.YPOS : 0.770122
IPM1H04B.XPOS : -2.08745
IPM1H04B.YPOS : 1.59804
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -1.58972
Target OTR y-position : 1.82039
Target OTR x-width : 0.770613
Target OTR y-width : 0.687435
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : -0.744219
Arc OTR y-position : 0.267455
Arc OTR x-width : 4.3873
Arc OTR y-width : 3.5402
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 600
Current Readback : 600.391