    User name a-onl

    Log entry time 15:01:47 on February 7, 2002

    Entry number 82101

    keyword=Start_Run_2219,Run_type=production,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=LH2 5G(e), beam current 30 uA, veto OFF, RCS magnet ON,daq_mode=coincidence,leftarm_p=3.992,leftarm_theta=21.59,photonarm_D=8.1,photonarm_angle=41.0,photonarm_p=1000,target_name=LH2 Rad,target_type=15LH2R
    Beginning-of-run EPICS data for Run Number 2219 at Thu Feb 7 15:01:29 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the calorimeter singles based on summers
    ; PS2 for the cosmic trigger for calorimeter 
    ; PS3 for the Left spectrometer based on T3 - S1+S2
    ; PS4 for the Left spectrometer redundant trigger S1+S2 or
    ;                        based on S1+S0 or S2+S0
    ; PS5 for Coinc. trigger based on S0 and Calo
    ; PS6 for laser 
    ; PS7 for the Left spectrometer based on S0, timed with calorimeter
    ; PS8 for pulser 
    ps1=39700,ps2=100000,ps3=60,ps4=66,ps5=1,ps6=1,ps7=1629,ps8=1024
     
    Left Arm Q1 power supply current : 3003.28
    Left Arm Q1 momentum : 3.99196
    Left Arm Q1 gauss meter : 0.2544
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1718.88
    Left Arm Q2 momentum : 3.99183
    Left Arm Q2 gauss meter : -0.904
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1497.62
    Left Arm D1 momentum : 3.99201
    Left Arm D1 NMR : 1.47894
    Left Arm Q3 power supply current : 1589.3
    Left Arm Q3 momentum : 3.99203
    Left Arm Q3 gauss meter : 0.7948
    Left Arm Q3 power supply polarity :
    Left Arm Top VDC Current : -1.80664
    Left Arm Bottom VDC Current : 3.17383
    Average current of the two cavities : 0.033713
    Current on Unser monitor : 6.70167
    Current on Upstream bcm : 0.0372297
    Current on Downstream bcm : 0.0301964
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    Tiefenbach Hall A energy : 5754.14
    Tiefenbach Hall C energy : 5753.75
    Delta(E)/E width (MV_AI_DXWID) : 0.367799
    MBSY1c Hall A Beam energy : 5766.17
    MBSY3c Hall C Beam energy : 5770.09
    MBSY1c magnet current (amp) : 241.051
    MBSY1c Bdl : 1.43895e+06
    Arc1 dp/p : 6.7216e-05
    Arc2 dp/p : -0.00143735
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.115234
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.117676
    HacL_alignROLL : 0.229086
    HacL_alignPITCH : -0.142211
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 22
    Left Arm Angle Vernier : -40.1
    Left Arm Scattering Angle : 21.5899
    IPM1C12.XPOS : 0
    IPM1C12.YPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Beam Half-wave plate (off=out) :
    Target OTR x-position : -1.49548
    Target OTR y-position : 1.8312
    Target OTR x-width : 0.822723
    Target OTR y-width : 0.699476
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -0.721596
    Arc OTR y-position : 0.255169
    Arc OTR x-width : 4.40439
    Arc OTR y-width : 3.54353
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407