User name a-onl
Log entry time 20:00:07 on February 9, 2002
Entry number 82414
keyword=Start_Run_2363,Run_type=optics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=Optics run,daq_mode=coincidence,leftarm_p=2.667,leftarm_theta=34.55,photonarm_D=18.0,photonarm_angle=23.0,photonarm_p=1400,target_name=C12 foil,target_type=Carbon Foil
Beginning-of-run EPICS data for Run Number 2363 at Sat Feb 9 19:59:51 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=50000,ps2=100000,ps3=1,ps4=100,ps5=1,ps6=1,ps7=4000,ps8=1024
Left Arm Q1 power supply current : 2006.62
Left Arm Q1 momentum : 2.6672
Left Arm Q1 gauss meter : 0.17022
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1148.24
Left Arm Q2 momentum : 2.6666
Left Arm Q2 gauss meter : -0.6048
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 922.34
Left Arm D1 momentum : 2.667
Left Arm D1 NMR : 0.987274
Left Arm Q3 power supply current : 1061.74
Left Arm Q3 momentum : 2.66689
Left Arm Q3 gauss meter : 0.5316
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : -0.732422
Average current of the two cavities : 45.1841
Current on Unser monitor : 51.673
Current on Upstream bcm : 44.9246
Current on Downstream bcm : 45.4436
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 45.2066
Tiefenbach Hall A energy : 5754.16
Tiefenbach Hall C energy : 5754.22
Delta(E)/E width (MV_AI_DXWID) : 0.905618
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5766.17
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.09
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 241.051
MBSY1c Bdl : 1.43895e+06
Arc1 dp/p : 0.000123541
Arc2 dp/p : -0.0014014
Left Arm Arm Collimator : 0.868506
HacL_HPE1313A:0_Ch58 : -0.162109
HacL_HPE1313A:0_Ch55 : 23.6328
HacL_HPE1313A:0_Ch54 : -0.240234
HacL_alignROLL : 0.120421
HacL_alignPITCH : -0.0999952
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 34.5
Left Arm Angle Vernier : 40
Left Arm Scattering Angle : 34.5515
IPM1C12.XPOS : 0.177369
IPM1C12.YPOS : 0.162546
IPM1H04A.XPOS : 1.17403
IPM1H04A.YPOS : -0.00842812
IPM1H04B.XPOS : -1.78163
IPM1H04B.YPOS : 0.550958
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : Yes
Target OTR In/Out :
Arc OTR x-position : 0.478995
Arc OTR y-position : -0.537423
Arc OTR x-width : 4.18991
Arc OTR y-width : 3.64291
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.224308