• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 15:05:42 on February 10, 2002

    Entry number 82504

    keyword=End_of_Run_2401
    ****************************
     Run Number: 2401
     End of Run Comment:
    Run_type=optics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=5H kinematics, Mag off veto off 40 uA, OPTICS RUN, calo th 1000,daq_mode=coincidence,leftarm_p=2.462,leftarm_theta=36.03,photonarm_D=18.0,photonarm_angle=23.0,photonarm_p=,target_name=,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=8000   ps2=1000000   ps3=1   ps4=20   ps5=1   ps6=1   ps7=600   ps8=1024   
    
    EVENTS[0]: 105552       [+]: 51824        [-]: 51771        
    TIME  [0]: 18.733 mins  [+]: 9.195 mins  [-]: 9.193 mins  
    LIVE  [0]: 102.03%      [+]: 102.16%      [-]: 101.93%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.8/6507.7 Hz   T2[0] : 0.0/0.1  Hz   T3[0] :83.5/83.5 Hz   T4[0] : 0.0/0.0  Hz   T5[0] : 1.8/1.8  Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 4.0/2411.0 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 0.8/6489.3 Hz   T2[+] : 0.0/0.1  Hz   T3[+] :83.4/83.4 Hz   T4[+] : 0.0/0.0  Hz   T5[+] : 1.8/1.8  Hz   T6[+] : 0.9/0.9  Hz   T7[+] : 4.0/2412.1 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 0.8/6500.8 Hz   T2[-] : 0.0/0.1  Hz   T3[-] :83.6/83.6 Hz   T4[-] : 0.0/0.0  Hz   T5[-] : 1.7/1.7  Hz   T6[-] : 0.9/0.9  Hz   T7[-] : 4.0/2409.3 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    914/7314455  T2[0] :      0/135      T3[0] :  93838/93838    T4[0] :      0/0        T5[0] :   1978/1978     T6[0] :   1088/1088     T7[0] :   4516/2709923  T8[0] :   1123/1150939  
    T1[+] :    447/3579998  T2[+] :      0/68       T3[+] :  46024/46024    T4[+] :      0/0        T5[+] :    971/971      T6[+] :    519/519      T7[+] :   2217/1330711  T8[+] :    551/564915   
    T1[-] :    448/3585857  T2[-] :      0/63       T3[-] :  46098/46098    T4[-] :      0/0        T5[-] :    965/965      T6[-] :    517/517      T7[-] :   2214/1328956  T8[-] :    551/564838   
    
    AVERAGE CURRENT
    BCM x1 : 32.6148uA  BCM x3 : 32.6786uA  BCM x10: 32.5640uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     -161 ppm     BCM u3 :   -158.4 ppm     BCM u10:   -162.8 ppm     
    BCM d1 :   -159.2 ppm     BCM d3 :   -154.7 ppm     BCM d10:   -157.5 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.03574        BCM u3 [0]:0.03588        BCM u10[0]:0.03592        
    BCM u1 [+]:0.01754        BCM u3 [+]:0.0176         BCM u10[+]:0.01763        
    BCM u1 [-]:0.01754        BCM u3 [-]:0.01761        BCM u10[-]:0.01763        
    
    BCM d1 [0]:0.03758        BCM d3 [0]:0.03758        BCM d10[0]:0.03728        
    BCM d1 [+]:0.01844        BCM d3 [+]:0.01844        BCM d10[+]:0.01829        
    BCM d1 [-]:0.01844        BCM d3 [-]:0.01845        BCM d10[-]:0.0183         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2401 at Sun Feb 10 15:05:36 EST 2002
    Left Arm D1 momentum : 4.28001
    Left Arm arm angle : 19.221
    Tiefenbach Hall A energy : 5754.14
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 4.24805
    Left Arm Bottom VDC Current : 0.683594
    Left Arm Q1 power supply current : 3220.14
    Left Arm Q1 momentum : 4.28021
    Left Arm Q1 gauss meter : 0.27255
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1843.28
    Left Arm Q2 momentum : 4.28072
    Left Arm Q2 gauss meter : -0.9689
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1668.75
    Left Arm D1 momentum : 4.28001
    Left Arm D1 NMR : 1.58581
    Left Arm Q3 power supply current : 1703.96
    Left Arm Q3 momentum : 4.28002
    Left Arm Q3 gauss meter : 0.8518
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0302857
    Current on Unser monitor : 8.12353
    Current on Upstream bcm : 0.0336192
    Current on Downstream bcm : 0.0269522
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5766.17
    MBSY1c magnet current (amp) : 241.051
    MBSY1c Bdl : 1.43895e+06
    MBSY3c Hall C Beam energy : 5770.09
    Tiefenbach Hall A energy : 5754.14
    Tiefenbach Hall C energy : 5753.74
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.125488
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.0410156
    HacL_alignROLL : 0.301807
    HacL_alignPITCH : -0.154991
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : OTR is Out
    Arc OTR x-position : 0.396973
    Arc OTR y-position : -0.552007
    Arc OTR x-width : 4.20679
    Arc OTR y-width : 3.6407
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286