    Log entry time 20:53:29 on February 11, 2002

    Entry number 82647

    keyword=End_of_Run_2464
    ****************************
     Run Number: 2464
     End of Run Comment:
    Run_type=optics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=5G(f+) kinematics, Mag OFF Veto off, 40uA, calo threshold 1050,daq_mode=coincidence,leftarm_p=4280,leftarm_theta=19.67,photonarm_D=8.1,photonarm_angle=43,photonarm_p=1050,target_name=optics,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=10000   ps2=1000000   ps3=1   ps4=25   ps5=1   ps6=1   ps7=1000   ps8=1024   
    
    EVENTS[0]: 54351        [+]: 26833        [-]: 26469        
    TIME  [0]: 7.074 mins  [+]: 3.470 mins  [-]: 3.470 mins  
    LIVE  [0]:  96.74%      [+]:  96.67%      [-]:  96.83%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.6/5965.8 Hz   T2[0] : 0.0/0.1  Hz   T3[0] :121.0/121.0 Hz   T4[0] : 4.0/100.2 Hz   T5[0] : 1.7/1.7  Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 3.0/3018.5 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 0.6/5941.6 Hz   T2[+] : 0.0/0.2  Hz   T3[+] :121.9/121.9 Hz   T4[+] : 4.0/100.0 Hz   T5[+] : 1.9/1.9  Hz   T6[+] : 1.0/1.0  Hz   T7[+] : 3.0/3011.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 0.6/5967.0 Hz   T2[-] : 0.0/0.1  Hz   T3[-] :120.1/120.1 Hz   T4[-] : 4.0/100.6 Hz   T5[-] : 1.6/1.6  Hz   T6[-] : 0.9/0.9  Hz   T7[-] : 3.0/3025.2 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    253/2532117  T2[0] :      0/48       T3[0] :  51377/51377    T4[0] :   1701/42531    T5[0] :    733/733      T6[0] :    411/411      T7[0] :   1281/1281149  T8[0] :    424/434624   
    T1[+] :    123/1236926  T2[+] :      0/33       T3[+] :  25375/25375    T4[+] :    832/20816    T5[+] :    386/386      T6[+] :    207/207      T7[+] :    626/626919   T8[+] :    208/213177   
    T1[-] :    124/1242286  T2[-] :      0/15       T3[-] :  25007/25007    T4[-] :    837/20934    T5[-] :    335/335      T6[-] :    196/196      T7[-] :    629/629834   T8[-] :    208/213191   
    
    AVERAGE CURRENT
    BCM x1 : 41.5222uA  BCM x3 : 41.6065uA  BCM x10: 41.4596uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -1420 ppm     BCM u3 :    -1385 ppm     BCM u10:    -1403 ppm     
    BCM d1 :    -1423 ppm     BCM d3 :    -1356 ppm     BCM d10:    -1331 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01718        BCM u3 [0]:0.01725        BCM u10[0]:0.01727        
    BCM u1 [+]:0.008412       BCM u3 [+]:0.008449       BCM u10[+]:0.008459       
    BCM u1 [-]:0.008437       BCM u3 [-]:0.008473       BCM u10[-]:0.008483       
    
    BCM d1 [0]:0.01807        BCM d3 [0]:0.01807        BCM d10[0]:0.01792        
    BCM d1 [+]:0.008848       BCM d3 [+]:0.008848       BCM d10[+]:0.008777       
    BCM d1 [-]:0.008874       BCM d3 [-]:0.008872       BCM d10[-]:0.008801       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2464 at Mon Feb 11 20:53:21 EST 2002
    Left Arm D1 momentum : 4.28001
    Left Arm arm angle : 19.6697
    Tiefenbach Hall A energy : 5754.1
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 4.44336
    Left Arm Bottom VDC Current : -2.19727
    Left Arm Q1 power supply current : 3220
    Left Arm Q1 momentum : 4.28003
    Left Arm Q1 gauss meter : 0.27252
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1843.07
    Left Arm Q2 momentum : 4.28023
    Left Arm Q2 gauss meter : -0.9686
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1668.7
    Left Arm D1 momentum :
    Left Arm D1 NMR : 1.5858
    Left Arm Q3 power supply current : 1703.96
    Left Arm Q3 momentum : 4.28003
    Left Arm Q3 gauss meter : 0.8518
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.0361007
    Current on Unser monitor : 7.53488
    Current on Upstream bcm : 0.0414305
    Current on Downstream bcm : 0.030771
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 5766.17
    MBSY1c magnet current (amp) : 241.051
    MBSY1c Bdl : 1.43895e+06
    MBSY3c Hall C Beam energy : 5770.09
    Tiefenbach Hall A energy : 5754.1
    Tiefenbach Hall C energy : 5754.26
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.10791
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.081543
    HacL_alignROLL : 0.261488
    HacL_alignPITCH : -0.17295
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : 0.374662
    Arc OTR y-position : -0.528888
    Arc OTR x-width : 4.19695
    Arc OTR y-width : 3.64092
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286