Entry number 82663
keyword=Start_Run_2470,Run_type=other,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=DVCS kinematics, 1.2uA, calo threshold -124.5 mV,daq_mode=coincidence,leftarm_p=3500,leftarm_theta=14.58,photonarm_D=18.0,photonarm_angle=20,photonarm_p=1000,target_name=LH2,target_type=15LH2
Beginning-of-run EPICS data for Run Number 2470 at Tue Feb 12 03:46:46 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=500,ps2=1000000,ps3=100,ps4=100,ps5=1,ps6=1,ps7=200,ps8=1024
Left Arm Q1 power supply current : 2633.36
Left Arm Q1 momentum : 3.50013
Left Arm Q1 gauss meter : -0.22251
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1506.92
Left Arm Q2 momentum : 3.49959
Left Arm Q2 gauss meter : 0.793
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 1253.71
Left Arm D1 momentum : 3.50003
Left Arm D1 NMR : 1.29638
Left Arm Q3 power supply current : 1393.32
Left Arm Q3 momentum : 3.49975
Left Arm Q3 gauss meter : -0.6968
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : -2.49023
Left Arm Bottom VDC Current : 3.41797
Average current of the two cavities : 1.22239
Current on Unser monitor : 8.23214
Current on Upstream bcm : 1.25485
Current on Downstream bcm : 1.21094
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 1.28071
Tiefenbach Hall A energy : 5754.16
Tiefenbach Hall C energy : 5752.05
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5766.17
MBSY3c Hall C Beam energy : 5770.09
MBSY1c magnet current (amp) : 241.051
MBSY1c Bdl : 1.43895e+06
Arc1 dp/p : 8.75959e-06
Arc2 dp/p : -0.00185975
Left Arm Arm Collimator : 0.868555
HacL_HPE1313A:0_Ch58 : -0.181152
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : 0.078125
HacL_alignROLL : 0.417617
HacL_alignPITCH : -0.103666
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : -42
Left Arm Scattering Angle : 14.5789
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0.472585
IPM1H04A.YPOS : 1.00171
IPM1H04B.XPOS : -2.04032
IPM1H04B.YPOS : 1.80334
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -0.745031
Target OTR y-position : 2.78787
Target OTR x-width : 0.0779591
Target OTR y-width : 0.600885
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : 0.38166
Arc OTR y-position : -0.546029
Arc OTR x-width : 4.20806
Arc OTR y-width : 3.64634
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.208286