Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 14:28:33 on February 13, 2002
Entry number 82763
keyword=Start_Run_2506,Run_type=cosmics,beam_energy=5.754,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=test scalers,daq_mode=coincidence,leftarm_p=3240,leftarm_theta=14.58,photonarm_D=5.3,photonarm_angle=20,photonarm_p=2490,target_name=???,target_type=15LH2
Beginning-of-run EPICS data for Run Number 2506 at Wed Feb 13 14:28:18 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=1000000,ps2=100,ps3=1,ps4=1,ps5=60000,ps6=60000,ps7=140,ps8=7024
Left Arm Q1 power supply current : 0.035
Left Arm Q1 momentum : 4.6522e-05
Left Arm Q1 gauss meter : 0.0002053
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 0.13213
Left Arm Q2 momentum : 0.000306852
Left Arm Q2 gauss meter : 0.0010778
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 0.136862
Left Arm D1 momentum : 0
Left Arm D1 NMR : 0.490206
Left Arm Q3 power supply current : 1.95804
Left Arm Q3 momentum : 0.00480901
Left Arm Q3 gauss meter : -5.99e-05
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : -2.05078
Left Arm Bottom VDC Current : 2.09961
Average current of the two cavities : 0.0348885
Current on Unser monitor : 7.71026
Current on Upstream bcm : 0.0411403
Current on Downstream bcm : 0.0286368
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 5753.96
Tiefenbach Hall C energy : 5753.4
Delta(E)/E width (MV_AI_DXWID) : 4.58995
MBSY1c Hall A Beam energy : 5766.17
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.09
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 0
MBSY1c Bdl : 1.43895e+06
Arc1 dp/p : 6.9394e-05
Arc2 dp/p : -0.00160496
Left Arm Arm Collimator : 0.868506
HacL_HPE1313A:0_Ch58 : -0.18457
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : 0.0756836
HacL_alignROLL : 0.413191
HacL_alignPITCH : -0.0995086
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : -42
Left Arm Scattering Angle : 14.5789
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : OTR is Out
Arc OTR x-position : 0.402275
Arc OTR y-position : -0.54891
Arc OTR x-width : 4.21133
Arc OTR y-width : 3.63814
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0