• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:41:55 on February 15, 2002

    Entry number 82829

    keyword=Start_Run_2531,Run_type=optics,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=Sieve slit in, raster off, optics run,daq_mode=coincidence,leftarm_p=2.885,leftarm_theta=16.912,photonarm_D=14.4,photonarm_angle=31,photonarm_p=1000,target_name=Carbon,target_type=Carbon Foil
    Beginning-of-run EPICS data for Run Number 2531 at Fri Feb 15 18:41:36 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the calorimeter singles based on summers
    ; PS2 for the cosmic trigger for calorimeter 
    ; PS3 for the Left spectrometer based on T3 - S1+S2
    ; PS4 for the Left spectrometer redundant trigger S1+S2 or
    ;                        based on S1+S0 or S2+S0
    ; PS5 for Coinc. trigger based on S0 and Calo
    ; PS6 for laser 
    ; PS7 for the Left spectrometer based on S0, timed with calorimeter
    ; PS8 for pulser 
    ps1=1000000,ps2=1000000,ps3=1,ps4=10,ps5=60000,ps6=1,ps7=10000,ps8=1024 
    Left Arm Q1 power supply current : 2170.77
    Left Arm Q1 momentum : 2.88539
    Left Arm Q1 gauss meter : -0.18352
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1242.29
    Left Arm Q2 momentum : 2.88503
    Left Arm Q2 gauss meter : 0.6546
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 1006.02
    Left Arm D1 momentum : 2.88503
    Left Arm D1 NMR : 1.06818
    Left Arm Q3 power supply current : 1148.5
    Left Arm Q3 momentum : 2.88483
    Left Arm Q3 gauss meter : -0.5749
    Left Arm Q3 power supply polarity : 1
    Left Arm Top VDC Current : 1.41602
    Left Arm Bottom VDC Current : 2.73438
    Average current of the two cavities : 40.9872
    Current on Unser monitor : 47.6041
    Current on Upstream bcm : 40.7003
    Current on Downstream bcm : 41.2742
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 41.2669
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5754.5
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 3483.85
    MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 5770.09
    MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 145.101
    MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 869400
    Arc1 dp/p : 0.000100024
    Arc2 dp/p : -0.00113577
    Left Arm Arm Collimator : 0.365918
    HacL_HPE1313A:0_Ch58 : -0.135254
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : 0.00830078
    HacL_alignROLL : 0.349451
    HacL_alignPITCH : -0.143964
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 17.5
    Left Arm Angle Vernier : -71
    Left Arm Scattering Angle : 16.9118
    IPM1C12.XPOS : -1.10815
    IPM1C12.YPOS : 0.387025
    IPM1H04A.XPOS : 0.241104
    IPM1H04A.YPOS : 0.536688
    IPM1H04B.XPOS : -0.0149228
    IPM1H04B.YPOS : 1.65551
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Beam Half-wave plate (off=out) :
    Target OTR x-position : 0.00600676
    Target OTR y-position : 1.98024
    Target OTR x-width : 0.255954
    Target OTR y-width : 0.297331
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -0.736862
    Arc OTR y-position : 0.252696
    Arc OTR x-width : 4.41261
    Arc OTR y-width : 3.54473
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.272374