• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:21:05 on February 15, 2002

    Entry number 82835

    keyword=End_of_Run_2533
    ****************************
     Run Number: 2533
     End of Run Comment:
    Run_type=optics,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=Sieve slit in, raster off, optics run,daq_mode=coincidence,leftarm_p=2.885,leftarm_theta=16.912,photonarm_D=14.4,photonarm_angle=31,photonarm_p=1000,target_name=Carbon,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=1000000   ps2=1000000   ps3=1   ps4=10   ps5=60000   ps6=1   ps7=10000   ps8=1024   
    
    EVENTS[0]: 300310       [+]: 147290       [-]: 147325       
    TIME  [0]: 11.435 mins  [+]: 5.611 mins  [-]: 5.610 mins  
    LIVE  [0]:  93.49%      [+]:  93.45%      [-]:  93.53%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 0.0/11877.4 Hz   T2[0] : 0.0/0.0  Hz   T3[0] :455.1/455.1 Hz   T4[0] :10.8/108.3 Hz   T5[0] : 0.0/3.1  Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 0.3/3175.5 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 0.0/11847.0 Hz   T2[+] : 0.0/0.0  Hz   T3[+] :455.0/455.0 Hz   T4[+] :10.9/109.1 Hz   T5[+] : 0.0/3.1  Hz   T6[+] : 0.9/0.9  Hz   T7[+] : 0.3/3177.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 0.0/11849.1 Hz   T2[-] : 0.0/0.0  Hz   T3[-] :454.9/454.9 Hz   T4[-] :10.7/107.2 Hz   T5[-] : 0.0/3.1  Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 0.3/3171.8 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :      8/8148700  T2[0] :      0/5        T3[0] : 312214/312214   T4[0] :   7432/74328    T5[0] :      0/2161     T6[0] :    665/665      T7[0] :    217/2178634  T8[0] :    686/702536   
    T1[+] :      3/3988225  T2[+] :      0/1        T3[+] : 153176/153176   T4[+] :   3674/36742    T5[+] :      0/1059     T6[+] :    319/319      T7[+] :    106/1069658  T8[+] :    336/344724   
    T1[-] :      3/3988770  T2[-] :      0/4        T3[-] : 153124/153124   T4[-] :   3609/36093    T5[-] :      0/1059     T6[-] :    333/333      T7[-] :    106/1067718  T8[-] :    336/344709   
    
    AVERAGE CURRENT
    BCM x1 : 41.1202uA  BCM x3 : 41.2056uA  BCM x10: 41.0638uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    191.2 ppm     BCM u3 :    175.6 ppm     BCM u10:      179 ppm     
    BCM d1 :    189.2 ppm     BCM d3 :    169.6 ppm     BCM d10:    164.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.02749        BCM u3 [0]:0.02761        BCM u10[0]:0.02764        
    BCM u1 [+]:0.01349        BCM u3 [+]:0.01355        BCM u10[+]:0.01357        
    BCM u1 [-]:0.01349        BCM u3 [-]:0.01354        BCM u10[-]:0.01356        
    
    BCM d1 [0]:0.02893        BCM d3 [0]:0.02893        BCM d10[0]:0.0287         
    BCM d1 [+]:0.0142         BCM d3 [+]:0.0142         BCM d10[+]:0.01409        
    BCM d1 [-]:0.01419        BCM d3 [-]:0.01419        BCM d10[-]:0.01408        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2533 at Fri Feb 15 19:20:56 EST 2002
    Left Arm D1 momentum : 2.78649
    Left Arm arm angle : 16.9118
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) :
    Left Arm Top VDC Current : 1.5625
    Left Arm Bottom VDC Current : -2.39258
    Left Arm Q1 power supply current : 2095.42
    Left Arm Q1 momentum : 2.78523
    Left Arm Q1 gauss meter : -0.17719
    Left Arm Q1 power supply polarity : 0
    Left Arm Q2 power supply current : 1198.89
    Left Arm Q2 momentum : 2.78423
    Left Arm Q2 gauss meter : 0.632
    Left Arm Q2 power supply polarity : 1
    Left Arm D1 power supply current : 950.09
    Left Arm D1 momentum : 2.76923
    Left Arm D1 NMR : 1.02521
    Left Arm Q3 power supply current : 1108.39
    Left Arm Q3 momentum : 2.78407
    Left Arm Q3 gauss meter : -0.5533
    Left Arm Q3 power supply polarity : 1
    Average current of the two cavities : 39.9545
    Current on Unser monitor : 47.2357
    Current on Upstream bcm : 39.7572
    Current on Downstream bcm : 40.1519
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 39.8659
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5770.09
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5753.29
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.396341
    IPM1H04A.XPOS : 0.523537
    IPM1H04A.YPOS : 1.05849
    IPM1H04B.XPOS : -0.327291
    IPM1H04B.YPOS : 1.89113
    Left Arm Arm Collimator : 0.366064
    HacL_HPE1313A:0_Ch58 : -0.135742
    HacL_HPE1313A:0_Ch55 : 23.3887
    HacL_HPE1313A:0_Ch54 : 0.00878906
    HacL_alignROLL : 0.349064
    HacL_alignPITCH : -0.143091
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.365967
    Target OTR x-position : -0.254227
    Target OTR y-position : 2.217
    Target OTR x-width : 0.219412
    Target OTR y-width : 0.221843
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -0.733531
    Arc OTR y-position : 0.274425
    Arc OTR x-width : 4.4082
    Arc OTR y-width : 3.54228
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.272374