User name a-onl
Log entry time 20:23:59 on February 15, 2002
Entry number 82842
keyword=Start_Run_2537,Run_type=optics,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=junk,daq_mode=coincidence,leftarm_p=2.785,leftarm_theta=16.912,photonarm_D=14.4,photonarm_angle=31,photonarm_p=1000,target_name=Carbon,target_type=Carbon Foil
Beginning-of-run EPICS data for Run Number 2537 at Fri Feb 15 20:23:40 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=1000000,ps2=1000000,ps3=1,ps4=10,ps5=60000,ps6=1,ps7=10000,ps8=1024
Left Arm Q1 power supply current : 2057.75
Left Arm Q1 momentum : 2.73517
Left Arm Q1 gauss meter : -0.17404
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1177.51
Left Arm Q2 momentum : 2.73459
Left Arm Q2 gauss meter : 0.6206
Left Arm Q2 power supply polarity : 1
Left Arm D1 power supply current : 948.856
Left Arm D1 momentum : 2.73501
Left Arm D1 NMR : 1.01251
Left Arm Q3 power supply current : 1088.7
Left Arm Q3 momentum : 2.73461
Left Arm Q3 gauss meter : -0.5449
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : 3.27148
Left Arm Bottom VDC Current : 2.24609
Average current of the two cavities : 10.0476
Current on Unser monitor : 19.4968
Current on Upstream bcm : 9.98487
Current on Downstream bcm : 10.1103
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 10.1977
Tiefenbach Hall A energy : 3477.94
Tiefenbach Hall C energy : 5753.62
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 3483.85
MBSY3c Hall C Beam energy : 5770.09
MBSY1c magnet current (amp) : 145.101
MBSY1c Bdl : 869400
Arc1 dp/p : 7.14453e-05
Arc2 dp/p : -0.00128446
Left Arm Arm Collimator : 0.868506
HacL_HPE1313A:0_Ch58 : -0.127441
HacL_HPE1313A:0_Ch55 : 23.291
HacL_HPE1313A:0_Ch54 : -0.20752
HacL_alignROLL : 0.149514
HacL_alignPITCH : -0.130475
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 25
Left Arm Angle Vernier : 41
Left Arm Scattering Angle : 25.0573
IPM1C12.XPOS : -0.562929
IPM1C12.YPOS : 0.355964
IPM1H04A.XPOS : 0.304474
IPM1H04A.YPOS : 0.579503
IPM1H04B.XPOS : -0.0485081
IPM1H04B.YPOS : 1.70658
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : 0.266716
Target OTR y-position : 2.18132
Target OTR x-width : 0.974859
Target OTR y-width : 1.00939
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -0.738809
Arc OTR y-position : 0.293674
Arc OTR x-width : 4.41072
Arc OTR y-width : 3.54817
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.272374