User name a-onl
Log entry time 00:01:02 on February 17, 2002
Entry number 82889
keyword=Start_Run_2555,Run_type=other,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Acceptance scan 3,daq_mode=L arm single,leftarm_p=2.657,leftarm_theta=25.057,photonarm_D=14.4,photonarm_angle=31,photonarm_p=1000,target_name=LH2 no rad,target_type=15LH2
Beginning-of-run EPICS data for Run Number 2555 at Sun Feb 17 00:00:39 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=1000000,ps2=1000000,ps3=1,ps4=1,ps5=60000,ps6=1,ps7=10000,ps8=1024
Left Arm Q1 power supply current : 1999.13
Left Arm Q1 momentum : 2.65725
Left Arm Q1 gauss meter : -0.16907
Left Arm Q1 power supply polarity : 0
Left Arm Q2 power supply current : 1144.08
Left Arm Q2 momentum : 2.65694
Left Arm Q2 gauss meter : 0.603
Left Arm Q2 power supply polarity :
Left Arm D1 power supply current : 919.878
Left Arm D1 momentum : 2.6571
Left Arm D1 NMR : 0.983604
Left Arm Q3 power supply current : 1057.81
Left Arm Q3 momentum : 2.65701
Left Arm Q3 gauss meter : -0.5294
Left Arm Q3 power supply polarity : 1
Left Arm Top VDC Current : 2.73438
Left Arm Bottom VDC Current : 2.14844
Average current of the two cavities : 9.64202
Current on Unser monitor : 17.2411
Current on Upstream bcm : 9.58712
Current on Downstream bcm : 9.69691
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 9.74433
Tiefenbach Hall A energy : 3477.94
Tiefenbach Hall C energy : 5752.01
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 3483.85
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 5770.09
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 145.101
MBSY1c Bdl : 869400
Arc1 dp/p : 5.40289e-05
Arc2 dp/p : -0.00133585
Left Arm Arm Collimator :
HacL_HPE1313A:0_Ch58 : -0.126465
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.192871
HacL_alignROLL : 0.162916
HacL_alignPITCH : -0.131049
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 25
Left Arm Angle Vernier : 41
Left Arm Scattering Angle : 25.0573
IPM1C12.XPOS : -0.00629115
IPM1C12.YPOS : 0.0302699
IPM1H04A.XPOS : 0.442461
IPM1H04A.YPOS : 0.626417
IPM1H04B.XPOS : -0.0142324
IPM1H04B.YPOS : 1.6592
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : 0.359405
Target OTR y-position : 2.1152
Target OTR x-width : 0.964628
Target OTR y-width : 1.02539
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -0.752159
Arc OTR y-position : 0.282743
Arc OTR x-width : 4.40787
Arc OTR y-width : 3.55036
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.288396