User name a-onl
Log entry time 04:17:04 on February 17, 2002
Entry number 82913
keyword=Start_Run_2565,Run_type=optics,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=Kinematics 3A Optics Target,daq_mode=coincidence,leftarm_p=1.928,leftarm_theta=37.44,photonarm_D=14.4,photonarm_angle=31,photonarm_p=1181,target_name=Optics Target,target_type=Carbon Foil
Beginning-of-run EPICS data for Run Number 2565 at Sun Feb 17 04:16:48 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=1000000,ps2=1000000,ps3=1,ps4=1,ps5=60000,ps6=1,ps7=10000,ps8=1024
Left Arm Q1 power supply current : 1450.44
Left Arm Q1 momentum : 1.92792
Left Arm Q1 gauss meter : 0.12317
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 830.298
Left Arm Q2 momentum : 1.92824
Left Arm Q2 gauss meter : -0.4375
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 652.973
Left Arm D1 momentum : 1.92795
Left Arm D1 NMR : 0.713423
Left Arm Q3 power supply current : 767.344
Left Arm Q3 momentum : 1.92743
Left Arm Q3 gauss meter : 0.3842
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 1.36719
Left Arm Bottom VDC Current : 2.68555
Average current of the two cavities : 24.845
Current on Unser monitor : 32.2675
Current on Upstream bcm : 24.6838
Current on Downstream bcm : 24.9824
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 25.0814
Tiefenbach Hall A energy : 3477.94
Tiefenbach Hall C energy : 5751.62
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3483.85
MBSY3c Hall C Beam energy : 5770.09
MBSY1c magnet current (amp) : 145.101
MBSY1c Bdl : 869400
Arc1 dp/p : 6.15205e-05
Arc2 dp/p : -0.00134922
Left Arm Arm Collimator : 0.868506
HacL_HPE1313A:0_Ch58 : -0.183105
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.256348
HacL_alignROLL : 0.105132
HacL_alignPITCH : -0.0809236
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 37.5
Left Arm Angle Vernier : 20.6
Left Arm Scattering Angle : 37.4397
IPM1C12.XPOS : -0.0159586
IPM1C12.YPOS : 0.0347073
IPM1H04A.XPOS : 0.361891
IPM1H04A.YPOS : 0.350582
IPM1H04B.XPOS : 0.0666491
IPM1H04B.YPOS : 1.69368
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : 0.175384
Target OTR y-position : 1.97224
Target OTR x-width : 0.230875
Target OTR y-width : 0.231753
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : -0.731661
Arc OTR y-position : 0.280299
Arc OTR x-width : 4.41675
Arc OTR y-width : 3.54811
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.272374