    User name a-onl

    Log entry time 04:17:04 on February 17, 2002

    Entry number 82913

    keyword=Start_Run_2565,Run_type=optics,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=off,comment_text=Kinematics 3A Optics Target,daq_mode=coincidence,leftarm_p=1.928,leftarm_theta=37.44,photonarm_D=14.4,photonarm_angle=31,photonarm_p=1181,target_name=Optics Target,target_type=Carbon Foil
    Beginning-of-run EPICS data for Run Number 2565 at Sun Feb 17 04:16:48 EST 2002
    ; (Integer!) prescale factors for runs. 
    ; This file is read at start of every run.
    ; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
    ; The default factor is essentially infinite. 
    ; ps8 = 65535 turns off the 1 kHz pulser on T8.
    ; Keep enough T2 and T4 to measure efficiency
    ; PS1 for the calorimeter singles based on summers
    ; PS2 for the cosmic trigger for calorimeter 
    ; PS3 for the Left spectrometer based on T3 - S1+S2
    ; PS4 for the Left spectrometer redundant trigger S1+S2 or
    ;                        based on S1+S0 or S2+S0
    ; PS5 for Coinc. trigger based on S0 and Calo
    ; PS6 for laser 
    ; PS7 for the Left spectrometer based on S0, timed with calorimeter
    ; PS8 for pulser 
    ps1=1000000,ps2=1000000,ps3=1,ps4=1,ps5=60000,ps6=1,ps7=10000,ps8=1024 
    Left Arm Q1 power supply current : 1450.44
    Left Arm Q1 momentum : 1.92792
    Left Arm Q1 gauss meter : 0.12317
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 830.298
    Left Arm Q2 momentum : 1.92824
    Left Arm Q2 gauss meter : -0.4375
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 652.973
    Left Arm D1 momentum : 1.92795
    Left Arm D1 NMR : 0.713423
    Left Arm Q3 power supply current : 767.344
    Left Arm Q3 momentum : 1.92743
    Left Arm Q3 gauss meter : 0.3842
    Left Arm Q3 power supply polarity : 0
    Left Arm Top VDC Current : 1.36719
    Left Arm Bottom VDC Current : 2.68555
    Average current of the two cavities : 24.845
    Current on Unser monitor : 32.2675
    Current on Upstream bcm : 24.6838
    Current on Downstream bcm : 24.9824
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 25.0814
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.62
    Delta(E)/E width (MV_AI_DXWID) : 0
    MBSY1c Hall A Beam energy : 3483.85
    MBSY3c Hall C Beam energy : 5770.09
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    Arc1 dp/p : 6.15205e-05
    Arc2 dp/p : -0.00134922
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.183105
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.256348
    HacL_alignROLL : 0.105132
    HacL_alignPITCH : -0.0809236
    HacL_alignHPT : -0
    Left Arm Angle Floor Angle : 37.5
    Left Arm Angle Vernier : 20.6
    Left Arm Scattering Angle : 37.4397
    IPM1C12.XPOS : -0.0159586
    IPM1C12.YPOS : 0.0347073
    IPM1H04A.XPOS : 0.361891
    IPM1H04A.YPOS : 0.350582
    IPM1H04B.XPOS : 0.0666491
    IPM1H04B.YPOS : 1.69368
    Survey X offset bpmA : -0.63
    Survey Y offset bpmA : -0.9
    Survey X offset bpmB : 0.77
    Survey Y offset bpmB : -1
    Wien angle :
    Helicity Mode ON/OFF Random/Toggle :
    Wien BDL :
    Wien field :
    Laser attenuation Hall A :
    Laser power Hall A :
    Half-wave plate (off=out) :
    Beam Half-wave plate (off=out) :
    Target OTR x-position : 0.175384
    Target OTR y-position : 1.97224
    Target OTR x-width : 0.230875
    Target OTR y-width : 0.231753
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : -0.731661
    Arc OTR y-position : 0.280299
    Arc OTR x-width : 4.41675
    Arc OTR y-width : 3.54811
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.272374