User name a-onl
Log entry time 04:48:08 on February 17, 2002
Entry number 82919
keyword=Start_Run_2568,Run_type=epcalib,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Kinematics 3A 15LH2 No R,daq_mode=coincidence,leftarm_p=1.928,leftarm_theta=37.44,photonarm_D=14.4,photonarm_angle=31,photonarm_p=1181,target_name=,target_type=15LH2
Beginning-of-run EPICS data for Run Number 2568 at Sun Feb 17 04:47:52 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=3000,ps2=1000000,ps3=1,ps4=1,ps5=1,ps6=1,ps7=300,ps8=1024
Left Arm Q1 power supply current : 1450.61
Left Arm Q1 momentum : 1.92815
Left Arm Q1 gauss meter :
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 830.071
Left Arm Q2 momentum : 1.92846
Left Arm Q2 gauss meter : -0.4375
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 652.977
Left Arm D1 momentum : 1.928
Left Arm D1 NMR : 0.713441
Left Arm Q3 power supply current : 767.583
Left Arm Q3 momentum : 1.92803
Left Arm Q3 gauss meter : 0.3843
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 2.09961
Left Arm Bottom VDC Current : -0.0976562
Average current of the two cavities : 0.0329534
Current on Unser monitor : 7.37961
Current on Upstream bcm : 0.0374512
Current on Downstream bcm : 0.0284557
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 3477.94
Tiefenbach Hall C energy : 5751.66
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3483.85
MBSY3c Hall C Beam energy : 5770.09
MBSY1c magnet current (amp) : 145.101
MBSY1c Bdl : 869400
Arc1 dp/p : 7.76193e-05
Arc2 dp/p : -0.00139364
Left Arm Arm Collimator : 0.868555
HacL_HPE1313A:0_Ch58 : -0.182129
HacL_HPE1313A:0_Ch55 : 23.1934
HacL_HPE1313A:0_Ch54 : -0.256348
HacL_alignROLL : 0.105503
HacL_alignPITCH : -0.0812867
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 37.5
Left Arm Angle Vernier : 20.6
Left Arm Scattering Angle : 37.4397
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle :
Helicity Mode ON/OFF Random/Toggle :
Wien BDL :
Wien field :
Laser attenuation Hall A :
Laser power Hall A :
Half-wave plate (off=out) :
Beam Half-wave plate (off=out) :
Target OTR x-position : -0.197108
Target OTR y-position : 1.36377
Target OTR x-width : 5.19461
Target OTR y-width : 2.97974
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : -0.761728
Arc OTR y-position : 0.29645
Arc OTR x-width : 4.4045
Arc OTR y-width : 3.54804
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 0
Current Readback : 0.272374