Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 15:19:10 on February 18, 2002
Entry number 83063
keyword=Start_Run_2631,Run_type=production,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Kinematics 3De, RCS magnet ON, veto off.,daq_mode=coincidence,leftarm_p=2752,leftarm_theta=22.53,photonarm_D=6.2,photonarm_angle=57,photonarm_p=400,target_name=LH2 rad,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 2631 at Mon Feb 18 15:18:58 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=150000,ps2=1000000,ps3=40,ps4=20,ps5=1,ps6=1,ps7=700,ps8=1024
Left Arm Q1 power supply current : 2070.64
Left Arm Q1 momentum : 2.75229
Left Arm Q1 gauss meter : 0.17567
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1185.21
Left Arm Q2 momentum : 2.75245
Left Arm Q2 gauss meter : -0.6241
Left Arm Q2 power supply polarity :
Left Arm D1 power supply current : 955.344
Left Arm D1 momentum : 2.752
Left Arm D1 NMR : 1.01882
Left Arm Q3 power supply current : 1095.61
Left Arm Q3 momentum : 2.75196
Left Arm Q3 gauss meter : 0.5484
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : -0.683594
Left Arm Bottom VDC Current : 0.683594
Average current of the two cavities : 10.2815
Current on Unser monitor : 17.7226
Current on Upstream bcm : 10.2322
Current on Downstream bcm : 10.3307
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 10.3372
Tiefenbach Hall A energy : 3477.94
Tiefenbach Hall C energy : 5751.9
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c Hall A Beam energy : 3483.85
MBSY3c Hall C Beam energy : 5770.09
MBSY1c magnet current (amp) : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 145.101
MBSY1c Bdl : 869400
Arc1 dp/p : 7.1866e-05
Arc2 dp/p : -0.00137028
Left Arm Arm Collimator : 0.868555
HacL_HPE1313A:0_Ch58 : -0.117676
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : -0.135254
HacL_alignROLL : 0.213402
HacL_alignPITCH : -0.138907
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 23
Left Arm Angle Vernier : -50.5
Left Arm Scattering Angle : 22.5299
IPM1C12.XPOS : -0.00119632
IPM1C12.YPOS : 0.029743
IPM1H04A.XPOS : 0.400582
IPM1H04A.YPOS : 0.468252
IPM1H04B.XPOS : 0.00337347
IPM1H04B.YPOS : 1.73529
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 60.4311
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1378.6
Wien field : 40.248
Laser attenuation Hall A : 240
Laser power Hall A : 71
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : 0.35702
Target OTR y-position : 2.12599
Target OTR x-width : 0.896582
Target OTR y-width : 0.944046
Target OTR data valid flag : No
Target OTR In/Out : MaxPix is Bad
Arc OTR x-position : 0.439284
Arc OTR y-position : -0.548993
Arc OTR x-width : 4.22116
Arc OTR y-width : 3.63379
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 600
Current Readback : 600.407