• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:34:40 on February 18, 2002

    Entry number 83102

    keyword=End_of_Run_2647
    ****************************
     Run Number: 2647
     End of Run Comment:
    Run_type=production,beam_energy=3.478,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=Kinematics 3Df, RCS magnet OFF, veto off.,daq_mode=coincidence,leftarm_p=2752,leftarm_theta=22.53,photonarm_D=6.2,photonarm_angle=57,photonarm_p=400,target_name=LH2 rad,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=54000   ps2=1000000   ps3=87   ps4=26   ps5=1   ps6=1   ps7=600   ps8=1024   
    
    EVENTS[0]: 101788       [+]: 50177        [-]: 49403        
    TIME  [0]: 4.662 mins  [+]: 2.287 mins  [-]: 2.285 mins  
    LIVE  [0]:  93.93%      [+]:  93.87%      [-]:  94.04%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 9.9/532821.1 Hz   T2[0] : 0.0/312.3 Hz   T3[0] : 9.6/837.7 Hz   T4[0] : 9.5/247.6 Hz   T5[0] :346.5/346.5 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.0/5988.1 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 9.9/533121.3 Hz   T2[+] : 0.0/311.3 Hz   T3[+] : 9.6/839.8 Hz   T4[+] : 9.5/246.5 Hz   T5[+] :348.5/348.5 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.0/6004.7 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 9.8/529600.3 Hz   T2[-] : 0.0/309.3 Hz   T3[-] : 9.6/833.5 Hz   T4[-] : 9.5/248.2 Hz   T5[-] :342.4/342.4 Hz   T6[-] : 0.9/0.9  Hz   T7[-] : 9.9/5963.6 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   2759/149032757  T2[0] :      0/87348    T3[0] :   2693/234301   T4[0] :   2664/69265    T5[0] :  96909/96909    T6[0] :    271/271      T7[0] :   2791/1674906  T8[0] :    279/286418   
    T1[+] :   1354/73155282  T2[+] :      0/42715    T3[+] :   1324/115240   T4[+] :   1301/33827    T5[+] :  47824/47824    T6[+] :    139/139      T7[+] :   1373/823971   T8[+] :    137/140514   
    T1[-] :   1344/72616263  T2[-] :      0/42412    T3[-] :   1313/114280   T4[-] :   1309/34037    T5[-] :  46944/46944    T6[-] :    127/127      T7[-] :   1362/817697   T8[-] :    137/140406   
    
    AVERAGE CURRENT
    BCM x1 : 9.7871 uA  BCM x3 : 4.7727 uA  BCM x10: 9.8021 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     3047 ppm     BCM u3 :     2962 ppm     BCM u10:     2990 ppm     
    BCM d1 :     3072 ppm     BCM d3 :    1E+39 ppm     BCM d10:     2967 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.002677       BCM u3 [0]:0.002676       BCM u10[0]:0.002683       
    BCM u1 [+]:0.001317       BCM u3 [+]:0.001317       BCM u10[+]:0.00132        
    BCM u1 [-]:0.001308       BCM u3 [-]:0.001308       BCM u10[-]:0.001311       
    
    BCM d1 [0]:0.002798       BCM d3 [0]:-6.315E-06     BCM d10[0]:0.0028         
    BCM d1 [+]:0.001377       BCM d3 [+]:-3.1E-06       BCM d10[+]:0.001378       
    BCM d1 [-]:0.001367       BCM d3 [-]:-3.093E-06     BCM d10[-]:0.001368       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2647 at Mon Feb 18 19:34:31 EST 2002
    Left Arm D1 momentum : 2.752
    Left Arm arm angle : 22.5299
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.585938
    Left Arm Bottom VDC Current : -0.634766
    Left Arm Q1 power supply current : 2070.64
    Left Arm Q1 momentum : 2.75229
    Left Arm Q1 gauss meter : 0.17559
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current :
    Left Arm Q2 momentum : 2.75208
    Left Arm Q2 gauss meter : -0.624
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 955.343
    Left Arm D1 momentum : 2.752
    Left Arm D1 NMR : 1.01882
    Left Arm Q3 power supply current : 1095.63
    Left Arm Q3 momentum : 2.75203
    Left Arm Q3 gauss meter : 0.5485
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 9.69862
    Current on Unser monitor : 18.6952
    Current on Upstream bcm : 9.64287
    Current on Downstream bcm : 9.75438
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 9.80961
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5770.09
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.64
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.0321767
    IPM1H04A.XPOS : 0.388774
    IPM1H04A.YPOS : 0.479512
    IPM1H04B.XPOS : -0.0763961
    IPM1H04B.YPOS : 1.72613
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.117188
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.134766
    HacL_alignROLL : 0.213402
    HacL_alignPITCH : -0.138907
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 244
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.257913
    Target OTR y-position : 2.13205
    Target OTR x-width : 0.90445
    Target OTR y-width : 0.944306
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : 0.42864
    Arc OTR y-position : -0.527836
    Arc OTR x-width : 4.20898
    Arc OTR y-width : 3.63366
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286