User name a-onl
Log entry time 03:57:06 on February 20, 2002
Entry number 83236
keyword=Start_Run_2703,Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=3F(e) production run, magnet on, veto off,daq_mode=coincidence,leftarm_p=3.118,leftarm_theta=16.36,photonarm_D=5.3,photonarm_angle=75,photonarm_p=300,target_name=15R,target_type=15LH2R
Beginning-of-run EPICS data for Run Number 2703 at Wed Feb 20 03:56:54 EST 2002
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string. (REALLY!!!)
; The default factor is essentially infinite.
; ps8 = 65535 turns off the 1 kHz pulser on T8.
; Keep enough T2 and T4 to measure efficiency
; PS1 for the calorimeter singles based on summers
; PS2 for the cosmic trigger for calorimeter
; PS3 for the Left spectrometer based on T3 - S1+S2
; PS4 for the Left spectrometer redundant trigger S1+S2 or
; based on S1+S0 or S2+S0
; PS5 for Coinc. trigger based on S0 and Calo
; PS6 for laser
; PS7 for the Left spectrometer based on S0, timed with calorimeter
; PS8 for pulser
ps1=48000,ps2=1000000,ps3=150,ps4=40,ps5=1,ps6=1,ps7=850,ps8=1024
Left Arm Q1 power supply current : 2345.74
Left Arm Q1 momentum : 3.11795
Left Arm Q1 gauss meter : 0.19893
Left Arm Q1 power supply polarity : 1
Left Arm Q2 power supply current : 1342.7
Left Arm Q2 momentum : 3.1182
Left Arm Q2 gauss meter : -0.7067
Left Arm Q2 power supply polarity : 0
Left Arm D1 power supply current : 1095.34
Left Arm D1 momentum : 3.11801
Left Arm D1 NMR : 1.15463
Left Arm Q3 power supply current : 1241.49
Left Arm Q3 momentum : 3.1184
Left Arm Q3 gauss meter : 0.6213
Left Arm Q3 power supply polarity : 0
Left Arm Top VDC Current : 0.683594
Left Arm Bottom VDC Current : 2.83203
Average current of the two cavities : 0.0298287
Current on Unser monitor : 8.55156
Current on Upstream bcm : 0.0332777
Current on Downstream bcm : 0.0263797
Upstream Cavity Coefficient : 76.7
Downstream Cavity Coefficient : 78.9
Current on IBC0L02 (source) : 0.00143682
Tiefenbach Hall A energy : 3477.94
Tiefenbach Hall C energy : 5750.73
Delta(E)/E width (MV_AI_DXWID) : 2.23234
MBSY1c Hall A Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C_energy Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 3483.85
MBSY3c Hall C Beam energy : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY3C_energy Accepted: 129.57.255.4 Rejected: iocsb4.acc.jlab.org " Source File: ../service.c Line Number: 897 .................................................................. 5770.09
MBSY1c magnet current (amp) : 145.101
MBSY1c Bdl : CA.Client.Diagnostic.............................................. Message: "Ambiguous channel host (multiple IOC's have a channel by that name)" Severity: "Warning" Context: "Channel: MBSY1C.BDL Accepted: iocsb4.acc.jlab.org Rejected: 129.57.255.4 " Source File: ../service.c Line Number: 897 .................................................................. 869400
Arc1 dp/p : 5.93308e-05
Arc2 dp/p : -0.00133924
Left Arm Arm Collimator : 0.868604
HacL_HPE1313A:0_Ch58 : -0.152832
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 :
HacL_alignROLL : 0.37888
HacL_alignPITCH : -0.12795
HacL_alignHPT : -0
Left Arm Angle Floor Angle : 16.5
Left Arm Angle Vernier : 6.9
Left Arm Scattering Angle : 16.3608
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
Wien angle : 60.4311
Helicity Mode ON/OFF Random/Toggle : OFF
Wien BDL : 1378.6
Wien field : 40.248
Laser attenuation Hall A : 252
Laser power Hall A : 71
Half-wave plate (off=out) : OUT
Beam Half-wave plate (off=out) : OUT
Target OTR x-position : -7.9589
Target OTR y-position : 7.73516
Target OTR x-width : 0
Target OTR y-width : -0
Target OTR data valid flag : No
Target OTR In/Out : Current is Low
Arc OTR x-position : 0.41578
Arc OTR y-position : -0.536745
Arc OTR x-width : 4.21318
Arc OTR y-width : 3.64891
Arc OTR data valid flag : No
Arc OTR In/Out : OTR is Out
Current Setpoint : 600
Current Readback : 600.391