• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:18:37 on February 21, 2002

    Entry number 83340

    keyword=End_of_Run_2746
    ****************************
     Run Number: 2746
     End of Run Comment:
    Run_type=optics,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=0,beam_raster=on,comment_text=3E(g) optics  , magnet off, veto off, ped supr.,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=optics,target_type=Carbon Foil
     
    
    PRESCALE FACTORS:ps1=50000   ps2=1000000   ps3=1   ps4=40   ps5=1   ps6=1   ps7=1000   ps8=1024   
    
    EVENTS[0]: 110405       [+]: 53832        [-]: 54435        
    TIME  [0]: 9.457 mins  [+]: 4.640 mins  [-]: 4.642 mins  
    LIVE  [0]:  95.12%      [+]:  95.16%      [-]:  95.12%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 1.3/64347.9 Hz   T2[0] : 0.0/2.6  Hz   T3[0] :188.8/188.8 Hz   T4[0] : 1.5/61.5 Hz   T5[0] : 9.3/9.3  Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 1.6/1645.0 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 1.3/64011.1 Hz   T2[+] : 0.0/2.5  Hz   T3[+] :187.6/187.6 Hz   T4[+] : 1.5/61.2 Hz   T5[+] : 9.2/9.2  Hz   T6[+] : 0.9/0.9  Hz   T7[+] : 1.6/1639.6 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 1.3/64377.0 Hz   T2[-] : 0.0/2.6  Hz   T3[-] :189.6/189.6 Hz   T4[-] : 1.5/61.7 Hz   T5[-] : 9.4/9.4  Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 1.6/1647.8 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :    730/36513762  T2[0] :      0/1460     T3[0] : 107116/107116   T4[0] :    872/34880    T5[0] :   5305/5305     T6[0] :    549/549      T7[0] :    933/933438   T8[0] :    567/581062   
    T1[+] :    356/17822471  T2[+] :      0/702      T3[+] :  52232/52232    T4[+] :    425/17030    T5[+] :   2561/2561     T6[+] :    261/261      T7[+] :    456/456523   T8[+] :    278/285110   
    T1[-] :    358/17929312  T2[-] :      0/729      T3[-] :  52792/52792    T4[-] :    429/17170    T5[-] :   2629/2629     T6[-] :    284/284      T7[-] :    458/458926   T8[-] :    278/285189   
    
    AVERAGE CURRENT
    BCM x1 : 20.1658uA  BCM x3 : 20.2076uA  BCM x10: 20.2081uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    -3668 ppm     BCM u3 :    -3592 ppm     BCM u10:    -3631 ppm     
    BCM d1 :    -3690 ppm     BCM d3 :    -3525 ppm     BCM d10:    -3605 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01116        BCM u3 [0]:0.01119        BCM u10[0]:0.01122        
    BCM u1 [+]:0.005456       BCM u3 [+]:0.005473       BCM u10[+]:0.005484       
    BCM u1 [-]:0.005498       BCM u3 [-]:0.005514       BCM u10[-]:0.005525       
    
    BCM d1 [0]:0.01172        BCM d3 [0]:0.01174        BCM d10[0]:0.01172        
    BCM d1 [+]:0.00573        BCM d3 [+]:0.005739       BCM d10[+]:0.005728       
    BCM d1 [-]:0.005774       BCM d3 [-]:0.005781       BCM d10[-]:0.005771       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2746 at Thu Feb 21 05:18:27 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 4.10156
    Left Arm Bottom VDC Current : -1.51367
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.5
    Left Arm Q2 momentum : 2.93892
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1025.88
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.04
    Left Arm Q3 momentum : 2.93892
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 19.7326
    Current on Unser monitor : 28.0202
    Current on Upstream bcm : 19.6361
    Current on Downstream bcm : 19.8291
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 19.8542
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5770.09
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5750.79
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.271813
    IPM1H04A.XPOS : 0.300776
    IPM1H04A.YPOS : 0.421429
    IPM1H04B.XPOS : 0.089607
    IPM1H04B.YPOS : 1.65801
    Left Arm Arm Collimator : 0.868457
    HacL_HPE1313A:0_Ch58 : -0.115234
    HacL_HPE1313A:0_Ch55 : 23.291
    HacL_HPE1313A:0_Ch54 : -0.0805664
    HacL_alignROLL : 0.263481
    HacL_alignPITCH : -0.163229
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 340
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.115211
    Target OTR y-position : 2.03991
    Target OTR x-width : 0.395448
    Target OTR y-width : 0.322626
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : 0.457765
    Arc OTR y-position : -0.54265
    Arc OTR x-width : 4.20076
    Arc OTR y-width : 3.63388
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 0
    Current Readback : 0.208286