     Run Number: 2850
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 992224       [+]: 486365       [-]: 485487       
    TIME  [0]: 10.016 mins  [+]: 4.917 mins  [-]: 4.916 mins  
    LIVE  [0]:  80.05%      [+]:  80.14%      [-]:  80.03%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :14.1/1410694.9 Hz   T2[0] : 0.0/2532.4 Hz   T3[0] :11.7/3502.1 Hz   T4[0] : 9.1/912.8 Hz   T5[0] :2015.5/2015.5 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.2/20375.6 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :14.1/1407333.0 Hz   T2[+] : 0.0/2518.1 Hz   T3[+] :11.6/3494.1 Hz   T4[+] : 9.1/912.4 Hz   T5[+] :2010.2/2010.2 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.2/20367.1 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :14.1/1406297.5 Hz   T2[-] : 0.0/2512.1 Hz   T3[-] :11.7/3505.1 Hz   T4[-] : 9.1/912.1 Hz   T5[-] :2009.6/2009.6 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.2/20364.8 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8478/847801477  T2[0] :      1/1521931  T3[0] :   7015/2104691  T4[0] :   5485/548567   T5[0] :1211275/1211275  T6[0] :    582/582      T7[0] :   6122/12245331  T8[0] :    600/615405   
    T1[+] :   4151/415156373  T2[+] :      0/742816   T3[+] :   3435/1030733  T4[+] :   2691/269149   T5[+] : 592997/592997   T6[+] :    286/286      T7[+] :   3004/6008188  T8[+] :    294/302075   
    T1[-] :   4148/414816555  T2[-] :      0/740991   T3[-] :   3446/1033892  T4[-] :   2690/269044   T5[-] : 592779/592779   T6[-] :    284/284      T7[-] :   3003/6007018  T8[-] :    294/302050   
    
    AVERAGE CURRENT
    BCM x1 : 29.3477uA  BCM x3 : 29.4083uA  BCM x10: 29.3911uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    240.3 ppm     BCM u3 :    227.2 ppm     BCM u10:    229.8 ppm     
    BCM d1 :      246 ppm     BCM d3 :    222.9 ppm     BCM d10:    225.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0172         BCM u3 [0]:0.01726        BCM u10[0]:0.01729        
    BCM u1 [+]:0.008442       BCM u3 [+]:0.008473       BCM u10[+]:0.008487       
    BCM u1 [-]:0.008437       BCM u3 [-]:0.008469       BCM u10[-]:0.008482       
    
    BCM d1 [0]:0.01808        BCM d3 [0]:0.01809        BCM d10[0]:0.01804        
    BCM d1 [+]:0.008873       BCM d3 [+]:0.008878       BCM d10[+]:0.008854       
    BCM d1 [-]:0.008868       BCM d3 [-]:0.008873       BCM d10[-]:0.008849       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2850 at Fri Feb 22 15:55:43 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.97852
    Left Arm Bottom VDC Current : 2.58789
    Left Arm Q1 power supply current : 2210.99
    Left Arm Q1 momentum : 2.93884
    Left Arm Q1 gauss meter : 0.18747
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.56
    Left Arm Q2 momentum : 2.93905
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.19
    Left Arm Q3 momentum : 2.9393
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8552
    Current on Unser monitor : 37.9285
    Current on Upstream bcm : 29.5999
    Current on Downstream bcm : 30.1104
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 29.9366
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5750.86
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.00434163
    IPM1H04A.XPOS : 0.324167
    IPM1H04A.YPOS : 0.405198
    IPM1H04B.XPOS : 0.0978483
    IPM1H04B.YPOS : 1.64792
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 23.1934
    HacL_HPE1313A:0_Ch54 : -0.0805664
    HacL_alignROLL : 0.262424
    HacL_alignPITCH : -0.163556
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 405
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.534448
    Target OTR y-position : 2.134
    Target OTR x-width : 0.502584
    Target OTR y-width : 0.563746
    Target OTR data valid flag : No
    Target OTR In/Out : MaxPix is Bad
    Arc OTR x-position : 0.400521
    Arc OTR y-position : -0.530221
    Arc OTR x-width : 4.20851
    Arc OTR y-width : 3.63912
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391