    User name a-onl

    Log entry time 02:25:23 on February 23, 2002

    Entry number 3630

    keyword=End_of_Run_2888
    ****************************
     Run Number: 2888
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 997173       [+]: 488423       [-]: 487950       
    TIME  [0]: 10.391 mins  [+]: 5.099 mins  [-]: 5.099 mins  
    LIVE  [0]:  80.25%      [+]:  80.37%      [-]:  80.24%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.5/1346338.6 Hz   T2[0] : 0.0/2330.0 Hz   T3[0] :11.6/3475.1 Hz   T4[0] : 9.1/907.6 Hz   T5[0] :1946.7/1946.7 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.1/20273.5 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.4/1343204.6 Hz   T2[+] : 0.0/2315.2 Hz   T3[+] :11.6/3476.6 Hz   T4[+] : 9.1/908.6 Hz   T5[+] :1940.4/1940.4 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.1/20275.5 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.4/1341910.5 Hz   T2[-] : 0.0/2311.8 Hz   T3[-] :11.6/3469.4 Hz   T4[-] : 9.1/906.1 Hz   T5[-] :1941.3/1941.3 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.1/20252.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8394/839402664  T2[0] :      1/1452664  T3[0] :   7222/2166631  T4[0] :   5658/565882   T5[0] :1213729/1213729  T6[0] :    604/604      T7[0] :   6319/12639962  T8[0] :    623/638434   
    T1[+] :   4109/410906483  T2[+] :      0/708266   T3[+] :   3545/1063541  T4[+] :   2779/277945   T5[+] : 593605/593605   T6[+] :    306/306      T7[+] :   3101/6202569  T8[+] :    305/313257   
    T1[-] :   4105/410566943  T2[-] :      0/707311   T3[-] :   3538/1061483  T4[-] :   2772/277216   T5[-] : 593969/593969   T6[-] :    298/298      T7[-] :   3098/6196502  T8[-] :    305/313300   
    
    AVERAGE CURRENT
    BCM x1 : 28.9793uA  BCM x3 : 29.0387uA  BCM x10: 29.0199uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    397.6 ppm     BCM u3 :    377.6 ppm     BCM u10:    379.6 ppm     
    BCM d1 :    393.8 ppm     BCM d3 :    371.3 ppm     BCM d10:    376.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01763        BCM u3 [0]:0.01769        BCM u10[0]:0.01772        
    BCM u1 [+]:0.00865        BCM u3 [+]:0.008681       BCM u10[+]:0.008696       
    BCM u1 [-]:0.008644       BCM u3 [-]:0.008676       BCM u10[-]:0.00869        
    
    BCM d1 [0]:0.01851        BCM d3 [0]:0.01852        BCM d10[0]:0.01847        
    BCM d1 [+]:0.009084       BCM d3 [+]:0.009089       BCM d10[+]:0.009063       
    BCM d1 [-]:0.009078       BCM d3 [-]:0.009084       BCM d10[-]:0.009058       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2888 at Sat Feb 23 02:25:14 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.92969
    Left Arm Bottom VDC Current : -0.244141
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18747
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.57
    Left Arm Q2 momentum : 2.93909
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1169.91
    Left Arm Q3 momentum : 2.93859
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8955
    Current on Unser monitor : 37.7431
    Current on Upstream bcm : 29.743
    Current on Downstream bcm : 30.0479
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.054
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.6
    Delta(E)/E width (MV_AI_DXWID) : 1.56159
    IPM1C12.XPOS : 0.0119294
    IPM1H04A.XPOS : 0.309747
    IPM1H04A.YPOS : 0.382082
    IPM1H04B.XPOS : 0.0705475
    IPM1H04B.YPOS : 1.66301
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.115234
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0810547
    HacL_alignROLL : 0.262349
    HacL_alignPITCH : -0.163003
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 420
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.362256
    Target OTR y-position : 2.11652
    Target OTR x-width : 0.892269
    Target OTR y-width : 0.963194
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.453689
    Arc OTR y-position : -0.520189
    Arc OTR x-width : 4.20049
    Arc OTR y-width : 3.63207
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391