• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 06:15:41 on February 23, 2002

    Entry number 3668

    keyword=End_of_Run_2910
    ****************************
     Run Number: 2910
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 993541       [+]: 487117       [-]: 485510       
    TIME  [0]: 9.926 mins  [+]: 4.870 mins  [-]: 4.872 mins  
    LIVE  [0]:  80.22%      [+]:  80.18%      [-]:  80.36%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :14.0/1397386.8 Hz   T2[0] : 0.0/2378.1 Hz   T3[0] :12.2/3663.3 Hz   T4[0] : 9.6/955.8 Hz   T5[0] :2031.1/2031.1 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.7/21333.7 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.9/1394932.5 Hz   T2[+] : 0.0/2368.0 Hz   T3[+] :12.2/3661.5 Hz   T4[+] : 9.5/954.6 Hz   T5[+] :2030.7/2030.7 Hz   T6[+] : 0.9/0.9  Hz   T7[+] :10.7/21341.3 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.9/1391684.7 Hz   T2[-] : 0.0/2353.8 Hz   T3[-] :12.2/3660.4 Hz   T4[-] : 9.6/955.9 Hz   T5[-] :2018.5/2018.5 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.6/21303.5 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8322/832239359  T2[0] :      1/1416295  T3[0] :   7272/2181755  T4[0] :   5692/569239   T5[0] :1209678/1209678  T6[0] :    576/576      T7[0] :   6352/12705695  T8[0] :    595/609862   
    T1[+] :   4076/407639072  T2[+] :      0/692002   T3[+] :   3566/1069997  T4[+] :   2789/278949   T5[+] : 593419/593419   T6[+] :    277/277      T7[+] :   3118/6236532  T8[+] :    292/299242   
    T1[-] :   4068/406805480  T2[-] :      0/688046   T3[-] :   3566/1069969  T4[-] :   2794/279409   T5[-] : 590032/590032   T6[-] :    296/296      T7[-] :   3113/6227268  T8[-] :    292/299327   
    
    AVERAGE CURRENT
    BCM x1 : 30.5641uA  BCM x3 : 30.6281uA  BCM x10: 30.6081uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    959.2 ppm     BCM u3 :    935.4 ppm     BCM u10:    943.2 ppm     
    BCM d1 :    962.6 ppm     BCM d3 :    920.8 ppm     BCM d10:    934.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01776        BCM u3 [0]:0.01782        BCM u10[0]:0.01785        
    BCM u1 [+]:0.008718       BCM u3 [+]:0.008751       BCM u10[+]:0.008766       
    BCM u1 [-]:0.008704       BCM u3 [-]:0.008737       BCM u10[-]:0.008751       
    
    BCM d1 [0]:0.01865        BCM d3 [0]:0.01866        BCM d10[0]:0.01861        
    BCM d1 [+]:0.009158       BCM d3 [+]:0.009162       BCM d10[+]:0.009136       
    BCM d1 [-]:0.009143       BCM d3 [-]:0.009148       BCM d10[-]:0.009122       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2910 at Sat Feb 23 06:15:34 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.36914
    Left Arm Bottom VDC Current : 2.34375
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18747
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.42
    Left Arm Q2 momentum : 2.93873
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.11
    Left Arm Q3 momentum : 2.9391
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 30.0746
    Current on Unser monitor : 38.2217
    Current on Upstream bcm : 29.9673
    Current on Downstream bcm : 30.182
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0367
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.74
    Delta(E)/E width (MV_AI_DXWID) : 1.50122
    IPM1C12.XPOS : 0.007413
    IPM1H04A.XPOS : 0.360578
    IPM1H04A.YPOS : 0.367546
    IPM1H04B.XPOS : 0.0169589
    IPM1H04B.YPOS : 1.65037
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0800781
    HacL_alignROLL : 0.261908
    HacL_alignPITCH : -0.163003
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 436
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.364587
    Target OTR y-position : 2.1159
    Target OTR x-width : 0.884416
    Target OTR y-width : 0.966195
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.398299
    Arc OTR y-position : -0.521676
    Arc OTR x-width : 4.21901
    Arc OTR y-width : 3.64579
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391