• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:33:46 on February 23, 2002

    Entry number 3702

    keyword=End_of_Run_2923
    ****************************
     Run Number: 2923
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 993752       [+]: 487382       [-]: 485449       
    TIME  [0]: 11.999 mins  [+]: 5.888 mins  [-]: 5.888 mins  
    LIVE  [0]:  80.31%      [+]:  80.33%      [-]:  80.39%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :11.7/1167723.6 Hz   T2[0] : 0.0/1987.5 Hz   T3[0] :10.2/3068.1 Hz   T4[0] : 8.0/801.3 Hz   T5[0] :1677.9/1677.9 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 8.9/17761.7 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :11.7/1165215.1 Hz   T2[+] : 0.0/1977.0 Hz   T3[+] :10.2/3063.5 Hz   T4[+] : 8.0/799.9 Hz   T5[+] :1676.7/1676.7 Hz   T6[+] : 1.1/1.1  Hz   T7[+] : 8.9/17755.7 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :11.6/1163369.1 Hz   T2[-] : 0.0/1969.0 Hz   T3[-] :10.2/3067.8 Hz   T4[-] : 8.0/801.6 Hz   T5[-] :1668.9/1668.9 Hz   T6[-] : 0.9/0.9  Hz   T7[-] : 8.9/17746.6 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8407/840725616  T2[0] :      1/1430974  T3[0] :   7363/2208939  T4[0] :   5768/576894   T5[0] :1208069/1208069  T6[0] :    697/697      T7[0] :   6393/12787888  T8[0] :    719/737249   
    T1[+] :   4116/411633840  T2[+] :      0/698416   T3[+] :   3607/1082251  T4[+] :   2825/282597   T5[+] : 592332/592332   T6[+] :    385/385      T7[+] :   3136/6272535  T8[+] :    353/361747   
    T1[-] :   4109/410960135  T2[-] :      0/695545   T3[-] :   3612/1083698  T4[-] :   2831/283180   T5[-] : 589529/589529   T6[-] :    306/306      T7[-] :   3134/6268992  T8[-] :    353/361728   
    
    AVERAGE CURRENT
    BCM x1 : 25.6595uA  BCM x3 : 25.7100uA  BCM x10: 25.6933uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    639.3 ppm     BCM u3 :      613 ppm     BCM u10:    619.7 ppm     
    BCM d1 :    639.2 ppm     BCM d3 :    600.8 ppm     BCM d10:    611.8 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01802        BCM u3 [0]:0.01809        BCM u10[0]:0.01812        
    BCM u1 [+]:0.008847       BCM u3 [+]:0.008878       BCM u10[+]:0.008893       
    BCM u1 [-]:0.008836       BCM u3 [-]:0.008866       BCM u10[-]:0.008881       
    
    BCM d1 [0]:0.01892        BCM d3 [0]:0.01894        BCM d10[0]:0.01888        
    BCM d1 [+]:0.009289       BCM d3 [+]:0.009295       BCM d10[+]:0.009268       
    BCM d1 [-]:0.009276       BCM d3 [-]:0.009283       BCM d10[-]:0.009256       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2923 at Sat Feb 23 09:33:39 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -0.585938
    Left Arm Bottom VDC Current : -1.51367
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18747
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.67
    Left Arm Q2 momentum : 2.9394
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.1
    Left Arm Q3 momentum : 2.93907
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity :
    Average current of the two cavities : 29.9629
    Current on Unser monitor : 38.3234
    Current on Upstream bcm : 29.7485
    Current on Downstream bcm : 30.1773
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.2484
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.51
    Delta(E)/E width (MV_AI_DXWID) : 1.58283
    IPM1C12.XPOS : 0.00336811
    IPM1H04A.XPOS : 0.346766
    IPM1H04A.YPOS : 0.343474
    IPM1H04B.XPOS : 0.0555029
    IPM1H04B.YPOS : 1.64049
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0805664
    HacL_alignROLL : 0.261908
    HacL_alignPITCH : -0.163003
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868457
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 417
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.375904
    Target OTR y-position : 2.11519
    Target OTR x-width : 0.8887
    Target OTR y-width : 0.967168
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.414542
    Arc OTR y-position : -0.529441
    Arc OTR x-width : 4.20413
    Arc OTR y-width : 3.63873
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391