• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 11:37:59 on February 23, 2002

    Entry number 3710

    keyword=End_of_Run_2927
    ****************************
     Run Number: 2927
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 857226       [+]: 420679       [-]: 418784       
    TIME  [0]: 9.122 mins  [+]: 4.475 mins  [-]: 4.478 mins  
    LIVE  [0]:  79.96%      [+]:  79.99%      [-]:  80.01%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.2/1322431.9 Hz   T2[0] : 0.0/2269.8 Hz   T3[0] :11.5/3444.8 Hz   T4[0] : 9.0/898.1 Hz   T5[0] :1913.2/1913.2 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.0/20012.9 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.2/1320153.7 Hz   T2[+] : 0.0/2257.8 Hz   T3[+] :11.5/3449.7 Hz   T4[+] : 9.0/897.2 Hz   T5[+] :1913.0/1913.0 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.0/20029.8 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.2/1317068.2 Hz   T2[-] : 0.0/2248.0 Hz   T3[-] :11.4/3435.3 Hz   T4[-] : 9.0/897.3 Hz   T5[-] :1902.8/1902.8 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.0/19976.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   7238/723801596  T2[0] :      1/1242313  T3[0] :   6284/1885424  T4[0] :   4915/491563   T5[0] :1047141/1047141  T6[0] :    530/530      T7[0] :   5476/10953588  T8[0] :    547/560462   
    T1[+] :   3544/354494786  T2[+] :      0/606269   T3[+] :   3087/926333   T4[+] :   2409/240929   T5[+] : 513676/513676   T6[+] :    258/258      T7[+] :   2689/5378498  T8[+] :    268/274970   
    T1[-] :   3538/353832179  T2[-] :      0/603937   T3[-] :   3076/922894   T4[-] :   2410/241069   T5[-] : 511179/511179   T6[-] :    264/264      T7[-] :   2683/5366692  T8[-] :    268/275099   
    
    AVERAGE CURRENT
    BCM x1 : 28.7599uA  BCM x3 : 28.8194uA  BCM x10: 28.7997uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1011 ppm     BCM u3 :    988.7 ppm     BCM u10:      994 ppm     
    BCM d1 :     1015 ppm     BCM d3 :    975.1 ppm     BCM d10:    986.8 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01536        BCM u3 [0]:0.01541        BCM u10[0]:0.01544        
    BCM u1 [+]:0.00754        BCM u3 [+]:0.007568       BCM u10[+]:0.00758        
    BCM u1 [-]:0.007528       BCM u3 [-]:0.007556       BCM u10[-]:0.007569       
    
    BCM d1 [0]:0.01612        BCM d3 [0]:0.01613        BCM d10[0]:0.01609        
    BCM d1 [+]:0.007917       BCM d3 [+]:0.007922       BCM d10[+]:0.007899       
    BCM d1 [-]:0.007905       BCM d3 [-]:0.00791        BCM d10[-]:0.007887       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2927 at Sat Feb 23 11:37:52 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 3.66211
    Left Arm Bottom VDC Current : 2.7832
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18747
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.27
    Left Arm Q2 momentum : 2.93839
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.14
    Left Arm Q3 momentum : 2.93919
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8333
    Current on Unser monitor : 37.9926
    Current on Upstream bcm : 29.6591
    Current on Downstream bcm : 30.0075
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 29.8987
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.58
    Delta(E)/E width (MV_AI_DXWID) : 1.6505
    IPM1C12.XPOS : 0.012738
    IPM1H04A.XPOS : 0.331428
    IPM1H04A.YPOS : 0.359848
    IPM1H04B.XPOS : 0.0607029
    IPM1H04B.YPOS : 1.65171
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0805664
    HacL_alignROLL : 0.262274
    HacL_alignPITCH : -0.163405
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 413
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.364942
    Target OTR y-position : 2.1155
    Target OTR x-width : 0.889082
    Target OTR y-width : 0.967216
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.441396
    Arc OTR y-position : -0.551161
    Arc OTR x-width : 4.21109
    Arc OTR y-width : 3.63615
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407