• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 12:06:52 on February 23, 2002

    Entry number 3713

    keyword=End_of_Run_2928
    ****************************
     Run Number: 2928
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 995876       [+]: 487819       [-]: 487507       
    TIME  [0]: 10.164 mins  [+]: 4.989 mins  [-]: 4.989 mins  
    LIVE  [0]:  80.60%      [+]:  80.68%      [-]:  80.61%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.7/1365341.4 Hz   T2[0] : 0.0/2328.8 Hz   T3[0] :11.9/3576.6 Hz   T4[0] : 9.3/932.2 Hz   T5[0] :1978.6/1978.6 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.4/20784.2 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.6/1362552.3 Hz   T2[+] : 0.0/2314.3 Hz   T3[+] :11.9/3575.4 Hz   T4[+] : 9.3/932.9 Hz   T5[+] :1972.6/1972.6 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.4/20785.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.6/1360125.6 Hz   T2[-] : 0.0/2309.1 Hz   T3[-] :11.9/3572.6 Hz   T4[-] : 9.3/931.2 Hz   T5[-] :1973.3/1973.3 Hz   T6[-] : 0.9/0.9  Hz   T7[-] :10.4/20764.2 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8326/832664937  T2[0] :      1/1420265  T3[0] :   7270/2181218  T4[0] :   5685/568530   T5[0] :1206690/1206690  T6[0] :    591/591      T7[0] :   6337/12675421  T8[0] :    609/624495   
    T1[+] :   4078/407867515  T2[+] :      0/692769   T3[+] :   3567/1070255  T4[+] :   2792/279255   T5[+] : 590478/590478   T6[+] :    312/312      T7[+] :   3110/6221908  T8[+] :    299/306525   
    T1[-] :   4071/407149068  T2[-] :      0/691222   T3[-] :   3564/1069454  T4[-] :   2787/278742   T5[-] : 590709/590709   T6[-] :    271/271      T7[-] :   3107/6215699  T8[-] :    299/306531   
    
    AVERAGE CURRENT
    BCM x1 : 29.8270uA  BCM x3 : 29.8890uA  BCM x10: 29.8689uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    730.8 ppm     BCM u3 :    709.5 ppm     BCM u10:    714.9 ppm     
    BCM d1 :    733.6 ppm     BCM d3 :    695.8 ppm     BCM d10:    705.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01774        BCM u3 [0]:0.01781        BCM u10[0]:0.01784        
    BCM u1 [+]:0.008713       BCM u3 [+]:0.008746       BCM u10[+]:0.00876        
    BCM u1 [-]:0.008701       BCM u3 [-]:0.008734       BCM u10[-]:0.008748       
    
    BCM d1 [0]:0.01864        BCM d3 [0]:0.01865        BCM d10[0]:0.01859        
    BCM d1 [+]:0.009151       BCM d3 [+]:0.009156       BCM d10[+]:0.009129       
    BCM d1 [-]:0.009138       BCM d3 [-]:0.009143       BCM d10[-]:0.009117       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2928 at Sat Feb 23 11:54:22 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.195312
    Left Arm Bottom VDC Current : 2.63672
    Left Arm Q1 power supply current : 2210.99
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18749
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.55
    Left Arm Q2 momentum : 2.93904
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.24
    Left Arm Q3 momentum : 2.93943
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8388
    Current on Unser monitor : 38.7376
    Current on Upstream bcm : 29.6686
    Current on Downstream bcm : 29.9566
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.1025
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.89
    Delta(E)/E width (MV_AI_DXWID) : 1.54561
    IPM1C12.XPOS : -0.279804
    IPM1H04A.XPOS : 0.311615
    IPM1H04A.YPOS : 0.364796
    IPM1H04B.XPOS : 0.0239417
    IPM1H04B.YPOS : 1.65642
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.115723
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0805664
    HacL_alignROLL : 0.261908
    HacL_alignPITCH : -0.162928
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 420
    Laser power Hall A :
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.362609
    Target OTR y-position : 2.12273
    Target OTR x-width : 0.880393
    Target OTR y-width : 0.967718
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.431949
    Arc OTR y-position : -0.510764
    Arc OTR x-width : 4.20017
    Arc OTR y-width : 3.64583
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407