• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:34:25 on February 23, 2002

    Entry number 3742

    keyword=End_of_Run_2942
    ****************************
     Run Number: 2942
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 994057       [+]: 487280       [-]: 486531       
    TIME  [0]: 10.031 mins  [+]: 4.924 mins  [-]: 4.924 mins  
    LIVE  [0]:  80.48%      [+]:  80.49%      [-]:  80.55%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.7/1372926.6 Hz   T2[0] : 0.0/2291.5 Hz   T3[0] :12.3/3679.6 Hz   T4[0] : 9.6/956.6 Hz   T5[0] :2003.9/2003.9 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.7/21419.2 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.7/1370248.5 Hz   T2[+] : 0.0/2277.2 Hz   T3[+] :12.2/3674.3 Hz   T4[+] : 9.6/958.0 Hz   T5[+] :2000.9/2000.9 Hz   T6[+] : 0.9/0.9  Hz   T7[+] :10.7/21421.8 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.7/1367907.7 Hz   T2[-] : 0.0/2273.1 Hz   T3[-] :12.3/3678.9 Hz   T4[-] : 9.5/954.0 Hz   T5[-] :1996.0/1996.0 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.7/21397.7 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8263/826316761  T2[0] :      1/1379147  T3[0] :   7382/2214644  T4[0] :   5757/575737   T5[0] :1206084/1206084  T6[0] :    583/583      T7[0] :   6445/12891499  T8[0] :    601/616310   
    T1[+] :   4048/404860261  T2[+] :      0/672829   T3[+] :   3618/1085621  T4[+] :   2830/283063   T5[+] : 591183/591183   T6[+] :    268/268      T7[+] :   3164/6329389  T8[+] :    295/302556   
    T1[-] :   4041/404165975  T2[-] :      0/671617   T3[-] :   3623/1086980  T4[-] :   2818/281861   T5[-] : 589739/589739   T6[-] :    304/304      T7[-] :   3161/6322236  T8[-] :    295/302554   
    
    AVERAGE CURRENT
    BCM x1 : 30.6331uA  BCM x3 : 30.6968uA  BCM x10: 30.6761uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    692.3 ppm     BCM u3 :    668.6 ppm     BCM u10:    675.2 ppm     
    BCM d1 :    690.7 ppm     BCM d3 :    656.6 ppm     BCM d10:    667.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01798        BCM u3 [0]:0.01805        BCM u10[0]:0.01808        
    BCM u1 [+]:0.008832       BCM u3 [+]:0.008865       BCM u10[+]:0.008879       
    BCM u1 [-]:0.008819       BCM u3 [-]:0.008853       BCM u10[-]:0.008867       
    
    BCM d1 [0]:0.01889        BCM d3 [0]:0.0189         BCM d10[0]:0.01885        
    BCM d1 [+]:0.009279       BCM d3 [+]:0.009284       BCM d10[+]:0.009257       
    BCM d1 [-]:0.009266       BCM d3 [-]:0.009271       BCM d10[-]:0.009245       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2942 at Sat Feb 23 14:34:17 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 3.41797
    Left Arm Bottom VDC Current : -1.17188
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18745
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.58
    Left Arm Q2 momentum : 2.9391
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.08
    Left Arm Q3 momentum : 2.93903
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.9875
    Current on Unser monitor : 38.7423
    Current on Upstream bcm : 29.8137
    Current on Downstream bcm : 30.1113
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0401
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.58
    Delta(E)/E width (MV_AI_DXWID) : 0.679577
    IPM1C12.XPOS : 0.00669754
    IPM1H04A.XPOS : 0.353413
    IPM1H04A.YPOS : 0.361982
    IPM1H04B.XPOS : 0.0826162
    IPM1H04B.YPOS : 1.63961
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.115234
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0810547
    HacL_alignROLL : 0.261833
    HacL_alignPITCH : -0.162928
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 421
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.375805
    Target OTR y-position : 2.11867
    Target OTR x-width : 0.893374
    Target OTR y-width : 0.963665
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.416029
    Arc OTR y-position : -0.529556
    Arc OTR x-width : 4.21717
    Arc OTR y-width : 3.64328
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391