    Log entry time 17:00:52 on February 23, 2002

    Entry number 3767

    keyword=End_of_Run_2954
    ****************************
     Run Number: 2954
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 993336       [+]: 487063       [-]: 485298       
    TIME  [0]: 10.031 mins  [+]: 4.922 mins  [-]: 4.922 mins  
    LIVE  [0]:  80.43%      [+]:  80.48%      [-]:  80.46%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.7/1372341.4 Hz   T2[0] : 0.0/2289.4 Hz   T3[0] :12.3/3676.8 Hz   T4[0] : 9.6/958.3 Hz   T5[0] :2003.8/2003.8 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.7/21417.7 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.7/1370154.5 Hz   T2[+] : 0.0/2277.9 Hz   T3[+] :12.3/3677.7 Hz   T4[+] : 9.6/958.6 Hz   T5[+] :2001.2/2001.2 Hz   T6[+] : 0.9/0.9  Hz   T7[+] :10.7/21433.3 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.7/1366487.2 Hz   T2[-] : 0.0/2267.3 Hz   T3[-] :12.2/3670.7 Hz   T4[-] : 9.6/957.0 Hz   T5[-] :1994.1/1994.1 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.7/21379.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8259/825977967  T2[0] :      1/1377950  T3[0] :   7376/2212993  T4[0] :   5767/576793   T5[0] :1206027/1206027  T6[0] :    583/583      T7[0] :   6445/12890761  T8[0] :    601/616320   
    T1[+] :   4046/404629111  T2[+] :      0/672716   T3[+] :   3620/1086092  T4[+] :   2830/283076   T5[+] : 591001/591001   T6[+] :    275/275      T7[+] :   3164/6329612  T8[+] :    295/302404   
    T1[-] :   4035/403567446  T2[-] :      0/669595   T3[-] :   3613/1084065  T4[-] :   2826/282636   T5[-] : 588925/588925   T6[-] :    301/301      T7[-] :   3157/6314176  T8[-] :    295/302420   
    
    AVERAGE CURRENT
    BCM x1 : 30.6206uA  BCM x3 : 30.6849uA  BCM x10: 30.6634uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1065 ppm     BCM u3 :     1035 ppm     BCM u10:     1046 ppm     
    BCM d1 :     1071 ppm     BCM d3 :     1017 ppm     BCM d10:     1034 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01798        BCM u3 [0]:0.01805        BCM u10[0]:0.01807        
    BCM u1 [+]:0.008828       BCM u3 [+]:0.008861       BCM u10[+]:0.008875       
    BCM u1 [-]:0.00881        BCM u3 [-]:0.008843       BCM u10[-]:0.008857       
    
    BCM d1 [0]:0.01888        BCM d3 [0]:0.01889        BCM d10[0]:0.01884        
    BCM d1 [+]:0.009272       BCM d3 [+]:0.009277       BCM d10[+]:0.00925        
    BCM d1 [-]:0.009253       BCM d3 [-]:0.009258       BCM d10[-]:0.009231       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2954 at Sat Feb 23 17:00:08 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 0.830078
    Left Arm Bottom VDC Current : -0.390625
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18747
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.76
    Left Arm Q2 momentum : 2.93953
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1169.97
    Left Arm Q3 momentum : 2.93874
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 30.1201
    Current on Unser monitor : 38.0252
    Current on Upstream bcm : 30.0281
    Current on Downstream bcm : 30.212
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.4405
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.88
    Delta(E)/E width (MV_AI_DXWID) : 0.61471
    IPM1C12.XPOS : -0.00482172
    IPM1H04A.XPOS : 0.342117
    IPM1H04A.YPOS : 0.38327
    IPM1H04B.XPOS : 0.0755837
    IPM1H04B.YPOS : 1.66368
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.115234
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.081543
    HacL_alignROLL : 0.261316
    HacL_alignPITCH : -0.162853
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 426
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.367779
    Target OTR y-position : 2.11238
    Target OTR x-width : 0.885617
    Target OTR y-width : 0.965416
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.395375
    Arc OTR y-position : -0.502614
    Arc OTR x-width : 4.20265
    Arc OTR y-width : 3.6425
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391