• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:30:59 on February 23, 2002

    Entry number 3781

    keyword=End_of_Run_2961
    ****************************
     Run Number: 2961
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 992092       [+]: 486414       [-]: 484741       
    TIME  [0]: 11.551 mins  [+]: 5.665 mins  [-]: 5.667 mins  
    LIVE  [0]:  73.84%      [+]:  73.93%      [-]:  73.84%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.0/1299827.2 Hz   T2[0] : 0.0/2155.1 Hz   T3[0] :11.7/3499.4 Hz   T4[0] : 9.1/911.3 Hz   T5[0] :1892.6/1892.6 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.2/20390.2 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.0/1297280.0 Hz   T2[+] : 0.0/2145.6 Hz   T3[+] :11.6/3494.8 Hz   T4[+] : 9.1/911.0 Hz   T5[+] :1889.5/1889.5 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.2/20395.7 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :12.9/1294819.5 Hz   T2[-] : 0.0/2132.6 Hz   T3[-] :11.7/3499.0 Hz   T4[-] : 9.1/910.2 Hz   T5[-] :1884.9/1884.9 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.2/20365.2 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   9008/900895797  T2[0] :      1/1493645  T3[0] :   8084/2425395  T4[0] :   6315/631581   T5[0] :1311768/1311768  T6[0] :    670/670      T7[0] :   7066/14132226  T8[0] :    693/709723   
    T1[+] :   4409/440981449  T2[+] :      0/729354   T3[+] :   3959/1187996  T4[+] :   3096/309659   T5[+] : 642301/642301   T6[+] :    330/330      T7[+] :   3466/6933061  T8[+] :    339/348086   
    T1[-] :   4402/440281630  T2[-] :      0/725164   T3[-] :   3965/1189783  T4[-] :   3095/309505   T5[-] : 640920/640920   T6[-] :    328/328      T7[-] :   3462/6924844  T8[-] :    340/348194   
    
    AVERAGE CURRENT
    BCM x1 : 29.1470uA  BCM x3 : 29.2065uA  BCM x10: 29.1868uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    764.4 ppm     BCM u3 :    740.3 ppm     BCM u10:    748.2 ppm     
    BCM d1 :    766.3 ppm     BCM d3 :      727 ppm     BCM d10:    739.9 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01971        BCM u3 [0]:0.01978        BCM u10[0]:0.01981        
    BCM u1 [+]:0.00967        BCM u3 [+]:0.009706       BCM u10[+]:0.009721       
    BCM u1 [-]:0.009658       BCM u3 [-]:0.009695       BCM u10[-]:0.00971        
    
    BCM d1 [0]:0.0207         BCM d3 [0]:0.02071        BCM d10[0]:0.02065        
    BCM d1 [+]:0.01016        BCM d3 [+]:0.01016        BCM d10[+]:0.01013        
    BCM d1 [-]:0.01014        BCM d3 [-]:0.01015        BCM d10[-]:0.01012        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2961 at Sat Feb 23 18:30:49 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 1.2207
    Left Arm Bottom VDC Current : -2.88086
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18749
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.41
    Left Arm Q2 momentum : 2.93871
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.26
    Left Arm Q3 momentum : 2.93947
    Left Arm Q3 gauss meter : 0.5858
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8508
    Current on Unser monitor : 37.8591
    Current on Upstream bcm : 29.7353
    Current on Downstream bcm : 29.9663
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0505
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.71
    Delta(E)/E width (MV_AI_DXWID) : 0.508239
    IPM1C12.XPOS : 0.0160787
    IPM1H04A.XPOS : 0.335918
    IPM1H04A.YPOS : 0.390729
    IPM1H04B.XPOS : 0.0670875
    IPM1H04B.YPOS : 1.65524
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.11377
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0810547
    HacL_alignROLL : 0.261833
    HacL_alignPITCH : -0.164359
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 433
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.362385
    Target OTR y-position : 2.1145
    Target OTR x-width : 0.880058
    Target OTR y-width : 0.966004
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.400928
    Arc OTR y-position : -0.531947
    Arc OTR x-width : 4.21343
    Arc OTR y-width : 3.63701
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391