• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 18:43:10 on February 23, 2002

    Entry number 3783

    keyword=End_of_Run_2962
    ****************************
     Run Number: 2962
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 994275       [+]: 487606       [-]: 485182       
    TIME  [0]: 10.419 mins  [+]: 5.110 mins  [-]: 5.110 mins  
    LIVE  [0]:  79.13%      [+]:  79.18%      [-]:  79.18%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.4/1341684.4 Hz   T2[0] : 0.0/2243.4 Hz   T3[0] :12.0/3611.6 Hz   T4[0] : 9.4/941.0 Hz   T5[0] :1962.5/1962.5 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.5/21043.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.4/1339137.8 Hz   T2[+] : 0.0/2229.9 Hz   T3[+] :12.0/3611.8 Hz   T4[+] : 9.4/941.9 Hz   T5[+] :1960.9/1960.9 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.5/21053.2 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.4/1336239.9 Hz   T2[-] : 0.0/2224.1 Hz   T3[-] :12.0/3605.2 Hz   T4[-] : 9.4/937.9 Hz   T5[-] :1951.3/1951.3 Hz   T6[-] : 0.9/0.9  Hz   T7[-] :10.5/21010.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8387/838762371  T2[0] :      1/1402474  T3[0] :   7526/2257800  T4[0] :   5882/588269   T5[0] :1226888/1226888  T6[0] :    605/605      T7[0] :   6577/13155429  T8[0] :    625/640160   
    T1[+] :   4106/410602661  T2[+] :      0/683737   T3[+] :   3691/1107448  T4[+] :   2888/288802   T5[+] : 601251/601251   T6[+] :    313/313      T7[+] :   3227/6455261  T8[+] :    306/313976   
    T1[-] :   4097/409729799  T2[-] :      0/681959   T3[-] :   3684/1105454  T4[-] :   2875/287597   T5[-] : 598315/598315   T6[-] :    281/281      T7[-] :   3221/6442404  T8[-] :    306/313988   
    
    AVERAGE CURRENT
    BCM x1 : 30.0576uA  BCM x3 : 30.1198uA  BCM x10: 30.0988uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    874.8 ppm     BCM u3 :    848.1 ppm     BCM u10:    855.2 ppm     
    BCM d1 :    872.2 ppm     BCM d3 :    834.7 ppm     BCM d10:    846.2 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01833        BCM u3 [0]:0.0184         BCM u10[0]:0.01843        
    BCM u1 [+]:0.008996       BCM u3 [+]:0.00903        BCM u10[+]:0.009044       
    BCM u1 [-]:0.008981       BCM u3 [-]:0.009015       BCM u10[-]:0.009029       
    
    BCM d1 [0]:0.01925        BCM d3 [0]:0.01926        BCM d10[0]:0.0192         
    BCM d1 [+]:0.009447       BCM d3 [+]:0.009452       BCM d10[+]:0.009425       
    BCM d1 [-]:0.009431       BCM d3 [-]:0.009437       BCM d10[-]:0.009409       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2962 at Sat Feb 23 18:43:02 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -1.51367
    Left Arm Bottom VDC Current : 2.49023
    Left Arm Q1 power supply current : 2210.99
    Left Arm Q1 momentum : 2.93884
    Left Arm Q1 gauss meter : 0.18745
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.42
    Left Arm Q2 momentum : 2.93874
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.06
    Left Arm Q3 momentum : 2.93898
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.9628
    Current on Unser monitor : 38.8787
    Current on Upstream bcm : 29.8652
    Current on Downstream bcm : 30.0604
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0609
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.71
    Delta(E)/E width (MV_AI_DXWID) : 0.502212
    IPM1C12.XPOS : 0.00143406
    IPM1H04A.XPOS : 0.328829
    IPM1H04A.YPOS : 0.339809
    IPM1H04B.XPOS : 0.0415459
    IPM1H04B.YPOS : 1.64773
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0810547
    HacL_alignROLL : 0.261391
    HacL_alignPITCH : -0.162928
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 430
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.361093
    Target OTR y-position : 2.11801
    Target OTR x-width : 0.882385
    Target OTR y-width : 0.966373
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.411604
    Arc OTR y-position : -0.516342
    Arc OTR x-width : 4.20681
    Arc OTR y-width : 3.64502
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391