• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:30:30 on February 23, 2002

    Entry number 3791

    keyword=End_of_Run_2966
    ****************************
     Run Number: 2966
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 993062       [+]: 486155       [-]: 485998       
    TIME  [0]: 10.090 mins  [+]: 4.949 mins  [-]: 4.950 mins  
    LIVE  [0]:  80.78%      [+]:  80.85%      [-]:  80.79%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.6/1358004.9 Hz   T2[0] : 0.0/2249.9 Hz   T3[0] :12.2/3668.3 Hz   T4[0] : 9.5/954.9 Hz   T5[0] :1982.7/1982.7 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.7/21363.2 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.6/1355339.0 Hz   T2[+] : 0.0/2233.4 Hz   T3[+] :12.2/3665.4 Hz   T4[+] : 9.6/955.7 Hz   T5[+] :1976.9/1976.9 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.7/21360.4 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.5/1352789.8 Hz   T2[-] : 0.0/2233.9 Hz   T3[-] :12.2/3665.9 Hz   T4[-] : 9.5/953.0 Hz   T5[-] :1977.6/1977.6 Hz   T6[-] : 0.9/0.9  Hz   T7[-] :10.7/21346.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8220/822098252  T2[0] :      1/1362004  T3[0] :   7402/2220674  T4[0] :   5780/578058   T5[0] :1200275/1200275  T6[0] :    586/586      T7[0] :   6466/12932696  T8[0] :    605/619901   
    T1[+] :   4024/402470816  T2[+] :      0/663219   T3[+] :   3628/1088435  T4[+] :   2837/283784   T5[+] : 587041/587041   T6[+] :    310/310      T7[+] :   3171/6343013  T8[+] :    296/304079   
    T1[-] :   4017/401762710  T2[-] :      0/663440   T3[-] :   3629/1088728  T4[-] :   2830/283037   T5[-] : 587324/587324   T6[-] :    263/263      T7[-] :   3169/6339768  T8[-] :    296/304116   
    
    AVERAGE CURRENT
    BCM x1 : 30.5026uA  BCM x3 : 30.5663uA  BCM x10: 30.5447uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    687.6 ppm     BCM u3 :    669.6 ppm     BCM u10:    676.1 ppm     
    BCM d1 :    699.3 ppm     BCM d3 :    655.8 ppm     BCM d10:      668 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01801        BCM u3 [0]:0.01808        BCM u10[0]:0.01811        
    BCM u1 [+]:0.008841       BCM u3 [+]:0.008874       BCM u10[+]:0.008888       
    BCM u1 [-]:0.00883        BCM u3 [-]:0.008863       BCM u10[-]:0.008877       
    
    BCM d1 [0]:0.01892        BCM d3 [0]:0.01893        BCM d10[0]:0.01887        
    BCM d1 [+]:0.009283       BCM d3 [+]:0.009288       BCM d10[+]:0.009261       
    BCM d1 [-]:0.009271       BCM d3 [-]:0.009277       BCM d10[-]:0.00925        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2966 at Sat Feb 23 19:30:22 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.56445
    Left Arm Bottom VDC Current : 3.125
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.68
    Left Arm Q2 momentum : 2.93935
    Left Arm Q2 gauss meter : -0.6664
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1169.94
    Left Arm Q3 momentum : 2.93867
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8825
    Current on Unser monitor : 38.2411
    Current on Upstream bcm : 29.7698
    Current on Downstream bcm : 29.9952
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0194
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.68
    Delta(E)/E width (MV_AI_DXWID) : 0.49746
    IPM1C12.XPOS : -0.000483453
    IPM1H04A.XPOS : 0.326291
    IPM1H04A.YPOS : 0.377128
    IPM1H04B.XPOS : 0.0431456
    IPM1H04B.YPOS : 1.66139
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.115723
    HacL_HPE1313A:0_Ch55 : 22.9492
    HacL_HPE1313A:0_Ch54 : -0.0810547
    HacL_alignROLL : 0.261391
    HacL_alignPITCH : -0.163882
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 426
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.367779
    Target OTR y-position : 2.11832
    Target OTR x-width : 0.894182
    Target OTR y-width : 0.966059
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : 0.397672
    Arc OTR y-position : -0.509649
    Arc OTR x-width : 4.20554
    Arc OTR y-width : 3.63029
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391