     Run Number: 2986
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 632275       [+]: 309357       [-]: 309370       
    TIME  [0]: 27.181 mins  [+]: 13.335 mins  [-]: 13.337 mins  
    LIVE  [0]:  80.67%      [+]:  80.82%      [-]:  80.63%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 3.3/334091.8 Hz   T2[0] : 0.0/519.7 Hz   T3[0] : 2.9/881.8 Hz   T4[0] : 2.4/237.9 Hz   T5[0] :467.2/467.2 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 2.8/5554.2 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 3.3/333386.3 Hz   T2[+] : 0.0/516.3 Hz   T3[+] : 2.9/882.3 Hz   T4[+] : 2.4/238.3 Hz   T5[+] :465.0/465.0 Hz   T6[+] : 1.0/1.0  Hz   T7[+] : 2.8/5556.3 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 3.3/332805.4 Hz   T2[-] : 0.0/515.3 Hz   T3[-] : 2.9/879.8 Hz   T4[-] : 2.4/237.3 Hz   T5[-] :466.1/466.1 Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 2.8/5545.1 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   5448/544865933  T2[0] :      0/847525   T3[0] :   4793/1438179  T4[0] :   3880/388035   T5[0] : 761894/761894   T6[0] :   1578/1578     T7[0] :   4529/9058350  T8[0] :   1630/1670028  
    T1[+] :   2667/266734783  T2[+] :      0/413083   T3[+] :   2353/705911   T4[+] :   1906/190659   T5[+] : 372059/372059   T6[+] :    788/788      T7[+] :   2222/4445500  T8[+] :    800/819279   
    T1[-] :   2663/266316480  T2[-] :      0/412325   T3[-] :   2346/704033   T4[-] :   1898/189881   T5[-] : 373017/373017   T6[-] :    762/762      T7[-] :   2218/4437308  T8[-] :    800/819422   
    
    AVERAGE CURRENT
    BCM x1 : 7.2857 uA  BCM x3 : 7.2840 uA  BCM x10: 7.2845 uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    785.5 ppm     BCM u3 :    747.7 ppm     BCM u10:    747.1 ppm     
    BCM d1 :    796.5 ppm     BCM d3 :    734.4 ppm     BCM d10:    738.7 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01163        BCM u3 [0]:0.01161        BCM u10[0]:0.01164        
    BCM u1 [+]:0.005709       BCM u3 [+]:0.005697       BCM u10[+]:0.005713       
    BCM u1 [-]:0.005702       BCM u3 [-]:0.005689       BCM u10[-]:0.005706       
    
    BCM d1 [0]:0.01213        BCM d3 [0]:0.01215        BCM d10[0]:0.01212        
    BCM d1 [+]:0.005952       BCM d3 [+]:0.005963       BCM d10[+]:0.005947       
    BCM d1 [-]:0.005944       BCM d3 [-]:0.005956       BCM d10[-]:0.00594        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 2986 at Sun Feb 24 00:24:12 EST 2002
    Left Arm D1 momentum : 2.93901
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.88086
    Left Arm Bottom VDC Current : -2.19727
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18749
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.48
    Left Arm Q2 momentum : 2.93887
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.93901
    Left Arm D1 NMR : 1.08821
    Left Arm Q3 power supply current : 1170.2
    Left Arm Q3 momentum : 2.93933
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 0.029204
    Current on Unser monitor : 7.22506
    Current on Upstream bcm : 0.0327767
    Current on Downstream bcm : 0.0256313
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 0.00143682
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5751.83
    Delta(E)/E width (MV_AI_DXWID) : 1.48784
    IPM1C12.XPOS : 0.0118965
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.261466
    HacL_alignPITCH : -0.163003
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868506
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 423
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : -7.9589
    Target OTR y-position : 7.73516
    Target OTR x-width : 0
    Target OTR y-width : -0
    Target OTR data valid flag : No
    Target OTR In/Out : Current is Low
    Arc OTR x-position : 0.447889
    Arc OTR y-position : -0.553722
    Arc OTR x-width : 4.1856
    Arc OTR y-width : 3.63813
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600