• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 09:41:51 on February 24, 2002

    Entry number 3919

    keyword=End_of_Run_3033
    ****************************
     Run Number: 3033
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 983828       [+]: 482046       [-]: 480916       
    TIME  [0]: 10.205 mins  [+]: 5.008 mins  [-]: 5.007 mins  
    LIVE  [0]:  81.04%      [+]:  81.04%      [-]:  81.14%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.2/1319396.1 Hz   T2[0] : 0.0/2128.5 Hz   T3[0] :12.2/3674.1 Hz   T4[0] : 9.6/957.3 Hz   T5[0] :1935.1/1935.1 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.7/21375.4 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.2/1316721.3 Hz   T2[+] : 0.0/2114.2 Hz   T3[+] :12.3/3675.6 Hz   T4[+] : 9.5/953.6 Hz   T5[+] :1932.1/1932.1 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.7/21373.3 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.1/1314171.5 Hz   T2[-] : 0.0/2111.0 Hz   T3[-] :12.2/3666.5 Hz   T4[-] : 9.6/959.7 Hz   T5[-] :1925.4/1925.4 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.7/21356.7 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8078/807849228  T2[0] :      1/1303272  T3[0] :   7498/2249612  T4[0] :   5861/586128   T5[0] :1184855/1184855  T6[0] :    592/592      T7[0] :   6543/13087884  T8[0] :    612/626982   
    T1[+] :   3956/395651596  T2[+] :      0/635289   T3[+] :   3681/1104462  T4[+] :   2865/286552   T5[+] : 580559/580559   T6[+] :    288/288      T7[+] :   3211/6422309  T8[+] :    300/307694   
    T1[-] :   3948/394805869  T2[-] :      0/634197   T3[-] :   3671/1101484  T4[-] :   2883/288326   T5[-] : 578427/578427   T6[-] :    286/286      T7[-] :   3208/6416006  T8[-] :    300/307632   
    
    AVERAGE CURRENT
    BCM x1 : 30.5011uA  BCM x3 : 30.5631uA  BCM x10: 30.5406uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :      785 ppm     BCM u3 :      764 ppm     BCM u10:    770.8 ppm     
    BCM d1 :    792.4 ppm     BCM d3 :    749.9 ppm     BCM d10:    762.3 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01822        BCM u3 [0]:0.01829        BCM u10[0]:0.01831        
    BCM u1 [+]:0.008945       BCM u3 [+]:0.008978       BCM u10[+]:0.008992       
    BCM u1 [-]:0.008929       BCM u3 [-]:0.008963       BCM u10[-]:0.008977       
    
    BCM d1 [0]:0.01913        BCM d3 [0]:0.01914        BCM d10[0]:0.01909        
    BCM d1 [+]:0.009394       BCM d3 [+]:0.009399       BCM d10[+]:0.009371       
    BCM d1 [-]:0.009378       BCM d3 [-]:0.009383       BCM d10[-]:0.009355       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3033 at Sun Feb 24 09:41:45 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.68555
    Left Arm Bottom VDC Current : -2.73438
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.26
    Left Arm Q2 momentum : 2.93838
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.74
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.09
    Left Arm Q3 momentum : 2.93906
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.9766
    Current on Unser monitor : 36.3625
    Current on Upstream bcm : 29.8714
    Current on Downstream bcm : 30.0819
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.2275
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.46
    Delta(E)/E width (MV_AI_DXWID) : 0.354438
    IPM1C12.XPOS : -0.541319
    IPM1H04A.XPOS : 0.310854
    IPM1H04A.YPOS : 0.358453
    IPM1H04B.XPOS : 0.0741138
    IPM1H04B.YPOS : 1.63013
    Left Arm Arm Collimator : 0.868506
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0820312
    HacL_alignROLL : 0.260066
    HacL_alignPITCH : -0.163882
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 426
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.361812
    Target OTR y-position : 2.10172
    Target OTR x-width : 0.89545
    Target OTR y-width : 0.963597
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.743216
    Arc OTR y-position : 0.278012
    Arc OTR x-width : 4.40235
    Arc OTR y-width : 3.54289
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391