     Run Number: 3053
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 983695       [+]: 482255       [-]: 480817       
    TIME  [0]: 10.368 mins  [+]: 5.088 mins  [-]: 5.086 mins  
    LIVE  [0]:  80.99%      [+]:  81.00%      [-]:  81.09%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :13.0/1301350.5 Hz   T2[0] : 0.0/2053.4 Hz   T3[0] :12.2/3663.6 Hz   T4[0] : 9.5/952.2 Hz   T5[0] :1905.1/1905.1 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.7/21313.6 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :13.0/1299158.1 Hz   T2[+] : 0.0/2043.6 Hz   T3[+] :12.2/3665.1 Hz   T4[+] : 9.5/951.6 Hz   T5[+] :1902.9/1902.9 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.7/21328.0 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :13.0/1295977.0 Hz   T2[-] : 0.0/2032.9 Hz   T3[-] :12.2/3656.9 Hz   T4[-] : 9.5/951.0 Hz   T5[-] :1895.6/1895.6 Hz   T6[-] : 0.9/0.9  Hz   T7[-] :10.6/21280.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8095/809535353  T2[0] :      1/1277395  T3[0] :   7596/2279005  T4[0] :   5923/592365   T5[0] :1185089/1185089  T6[0] :    602/602      T7[0] :   6629/13258637  T8[0] :    622/637003   
    T1[+] :   3966/396636521  T2[+] :      0/623930   T3[+] :   3729/1118975  T4[+] :   2905/290523   T5[+] : 580955/580955   T6[+] :    293/293      T7[+] :   3255/6511505  T8[+] :    305/312630   
    T1[-] :   3955/395503323  T2[-] :      0/620383   T3[-] :   3719/1115994  T4[-] :   2902/290211   T5[-] : 578506/578506   T6[-] :    278/278      T7[-] :   3247/6494466  T8[-] :    305/312502   
    
    AVERAGE CURRENT
    BCM x1 : 30.4174uA  BCM x3 : 30.4787uA  BCM x10: 30.4568uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :    974.3 ppm     BCM u3 :    936.6 ppm     BCM u10:    949.5 ppm     
    BCM d1 :    974.4 ppm     BCM d3 :    916.7 ppm     BCM d10:    936.1 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01846        BCM u3 [0]:0.01853        BCM u10[0]:0.01855        
    BCM u1 [+]:0.009066       BCM u3 [+]:0.009099       BCM u10[+]:0.009114       
    BCM u1 [-]:0.009044       BCM u3 [-]:0.009079       BCM u10[-]:0.009093       
    
    BCM d1 [0]:0.01939        BCM d3 [0]:0.01939        BCM d10[0]:0.01934        
    BCM d1 [+]:0.009522       BCM d3 [+]:0.009526       BCM d10[+]:0.009498       
    BCM d1 [-]:0.0095         BCM d3 [-]:0.009505       BCM d10[-]:0.009477       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3053 at Sun Feb 24 13:36:55 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 3.32031
    Left Arm Bottom VDC Current : 1.46484
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18745
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.45
    Left Arm Q2 momentum : 2.9388
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current :
    Left Arm Q3 momentum : 2.93898
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8201
    Current on Unser monitor : 37.4742
    Current on Upstream bcm : 29.682
    Current on Downstream bcm : 29.9583
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0609
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.03
    Delta(E)/E width (MV_AI_DXWID) : 0.368495
    IPM1C12.XPOS : -0.00691448
    IPM1H04A.XPOS : 0.30439
    IPM1H04A.YPOS : 0.370365
    IPM1H04B.XPOS : 0.0322127
    IPM1H04B.YPOS : 1.65008
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : -0.0820312
    HacL_alignROLL : 0.260583
    HacL_alignPITCH : -0.16348
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 419
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.372048
    Target OTR y-position : 2.12088
    Target OTR x-width : 0.883826
    Target OTR y-width : 0.967143
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.734966
    Arc OTR y-position : 0.266428
    Arc OTR x-width : 4.40567
    Arc OTR y-width : 3.54185
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391