• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 14:15:21 on February 24, 2002

    Entry number 3964

    keyword=End_of_Run_3056
    ****************************
     Run Number: 3056
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 984964       [+]: 482001       [-]: 482365       
    TIME  [0]: 10.971 mins  [+]: 5.384 mins  [-]: 5.385 mins  
    LIVE  [0]:  81.18%      [+]:  81.20%      [-]:  81.26%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :12.3/1227156.6 Hz   T2[0] : 0.0/1937.2 Hz   T3[0] :11.5/3455.7 Hz   T4[0] : 9.0/898.8 Hz   T5[0] :1798.5/1798.5 Hz   T6[0] : 1.0/1.0  Hz   T7[0] :10.1/20112.8 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :12.3/1225409.0 Hz   T2[+] : 0.0/1933.0 Hz   T3[+] :11.5/3451.2 Hz   T4[+] : 9.0/899.1 Hz   T5[+] :1792.6/1792.6 Hz   T6[+] : 1.0/1.0  Hz   T7[+] :10.1/20122.6 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :12.2/1221582.5 Hz   T2[-] : 0.0/1913.5 Hz   T3[-] :11.5/3453.8 Hz   T4[-] : 9.0/897.7 Hz   T5[-] :1792.6/1792.6 Hz   T6[-] : 1.0/1.0  Hz   T7[-] :10.0/20078.9 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8077/807768608  T2[0] :      1/1275183  T3[0] :   7582/2274672  T4[0] :   5916/591657   T5[0] :1183868/1183868  T6[0] :    637/637      T7[0] :   6619/13239108  T8[0] :    658/674042   
    T1[+] :   3958/395872923  T2[+] :      0/624466   T3[+] :   3716/1114929  T4[+] :   2904/290444   T5[+] : 579112/579112   T6[+] :    308/308      T7[+] :   3250/6500682  T8[+] :    323/330807   
    T1[-] :   3946/394670149  T2[-] :      0/618204   T3[-] :   3719/1115870  T4[-] :   2900/290031   T5[-] : 579167/579167   T6[-] :    314/314      T7[-] :   3243/6487101  T8[-] :    323/330835   
    
    AVERAGE CURRENT
    BCM x1 : 28.7058uA  BCM x3 : 28.7627uA  BCM x10: 28.7419uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1275 ppm     BCM u3 :     1244 ppm     BCM u10:     1255 ppm     
    BCM d1 :     1277 ppm     BCM d3 :     1223 ppm     BCM d10:     1242 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01843        BCM u3 [0]:0.0185         BCM u10[0]:0.01853        
    BCM u1 [+]:0.009056       BCM u3 [+]:0.009088       BCM u10[+]:0.009103       
    BCM u1 [-]:0.009033       BCM u3 [-]:0.009066       BCM u10[-]:0.009081       
    
    BCM d1 [0]:0.01936        BCM d3 [0]:0.01937        BCM d10[0]:0.01931        
    BCM d1 [+]:0.00951        BCM d3 [+]:0.009514       BCM d10[+]:0.009486       
    BCM d1 [-]:0.009486       BCM d3 [-]:0.009492       BCM d10[-]:0.009464       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3056 at Sun Feb 24 14:15:14 EST 2002
    Left Arm D1 momentum : 2.93899
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : 2.97852
    Left Arm Bottom VDC Current : 2.24609
    Left Arm Q1 power supply current : 2211.09
    Left Arm Q1 momentum : 2.93898
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.47
    Left Arm Q2 momentum : 2.93886
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.93899
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.1
    Left Arm Q3 momentum : 2.93908
    Left Arm Q3 gauss meter : 0.5857
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8341
    Current on Unser monitor : 37.665
    Current on Upstream bcm : 29.696
    Current on Downstream bcm : 29.9722
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.0263
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.1
    Delta(E)/E width (MV_AI_DXWID) : 0.40458
    IPM1C12.XPOS : 0.0017896
    IPM1H04A.XPOS : 0.321414
    IPM1H04A.YPOS : 0.358565
    IPM1H04B.XPOS : 0.0565177
    IPM1H04B.YPOS : 1.64442
    Left Arm Arm Collimator : 0.868555
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.260583
    HacL_alignPITCH : -0.163958
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868555
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 419
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.372578
    Target OTR y-position : 2.11697
    Target OTR x-width : 0.88872
    Target OTR y-width : 0.969382
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.754555
    Arc OTR y-position : 0.316328
    Arc OTR x-width : 4.39747
    Arc OTR y-width : 3.54157
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.391