    Log entry time 14:31:48 on February 24, 2002

    Entry number 3966

    keyword=End_of_Run_3057
    ****************************
     Run Number: 3057
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 984929       [+]: 483754       [-]: 480647       
    TIME  [0]: 15.141 mins  [+]: 7.431 mins  [-]: 7.431 mins  
    LIVE  [0]:  81.21%      [+]:  81.28%      [-]:  81.23%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] : 8.9/894331.6 Hz   T2[0] : 0.0/1398.0 Hz   T3[0] : 8.4/2510.9 Hz   T4[0] : 6.6/659.2 Hz   T5[0] :1301.8/1301.8 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 7.4/14815.1 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] : 8.9/893103.3 Hz   T2[+] : 0.0/1392.8 Hz   T3[+] : 8.4/2514.5 Hz   T4[+] : 6.6/658.8 Hz   T5[+] :1301.6/1301.6 Hz   T6[+] : 1.0/1.0  Hz   T7[+] : 7.4/14827.2 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] : 8.9/890325.6 Hz   T2[-] : 0.0/1382.7 Hz   T3[-] : 8.3/2504.3 Hz   T4[-] : 6.6/659.0 Hz   T5[-] :1294.0/1294.0 Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 7.4/14791.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8124/812451338  T2[0] :      1/1270030  T3[0] :   7603/2281059  T4[0] :   5988/598815   T5[0] :1182592/1182592  T6[0] :    879/879      T7[0] :   6729/13458728  T8[0] :    908/930248   
    T1[+] :   3982/398214197  T2[+] :      0/621037   T3[+] :   3737/1121169  T4[+] :   2937/293734   T5[+] : 580361/580361   T6[+] :    435/435      T7[+] :   3305/6611109  T8[+] :    445/456578   
    T1[-] :   3969/396953058  T2[-] :      0/616460   T3[-] :   3721/1116568  T4[-] :   2938/293812   T5[-] : 576945/576945   T6[-] :    427/427      T7[-] :   3297/6594771  T8[-] :    445/456552   
    
    AVERAGE CURRENT
    BCM x1 : 20.8667uA  BCM x3 : 20.9016uA  BCM x10: 20.8883uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1270 ppm     BCM u3 :     1239 ppm     BCM u10:     1250 ppm     
    BCM d1 :     1278 ppm     BCM d3 :     1215 ppm     BCM d10:     1236 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.0185         BCM u3 [0]:0.01855        BCM u10[0]:0.01859        
    BCM u1 [+]:0.00909        BCM u3 [+]:0.009116       BCM u10[+]:0.009132       
    BCM u1 [-]:0.009066       BCM u3 [-]:0.009093       BCM u10[-]:0.009108       
    
    BCM d1 [0]:0.01941        BCM d3 [0]:0.01942        BCM d10[0]:0.01937        
    BCM d1 [+]:0.009538       BCM d3 [+]:0.009543       BCM d10[+]:0.009515       
    BCM d1 [-]:0.009513       BCM d3 [-]:0.009519       BCM d10[-]:0.009491       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3057 at Sun Feb 24 14:31:40 EST 2002
    Left Arm D1 momentum : 2.939
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -2.83203
    Left Arm Bottom VDC Current : 1.31836
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18746
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.55
    Left Arm Q2 momentum : 2.93926
    Left Arm Q2 gauss meter : -0.6663
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.939
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.08
    Left Arm Q3 momentum : 2.93902
    Left Arm Q3 gauss meter : 0.5858
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.8995
    Current on Unser monitor : 38.2887
    Current on Upstream bcm : 29.7386
    Current on Downstream bcm : 30.0604
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 30.231
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.04
    Delta(E)/E width (MV_AI_DXWID) : 0.427178
    IPM1C12.XPOS : 0.00678933
    IPM1H04A.XPOS : 0.302958
    IPM1H04A.YPOS : 0.382463
    IPM1H04B.XPOS : 0.0779202
    IPM1H04B.YPOS : 1.65248
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.114258
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0825195
    HacL_alignROLL : 0.260508
    HacL_alignPITCH : -0.162928
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 420
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.37693
    Target OTR y-position : 2.12339
    Target OTR x-width : 0.893319
    Target OTR y-width : 0.965794
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.743542
    Arc OTR y-position : 0.291636
    Arc OTR x-width : 4.40899
    Arc OTR y-width : 3.54462
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407