    Log entry time 16:54:01 on February 24, 2002

    Entry number 3991

    keyword=End_of_Run_3069
    ****************************
     Run Number: 3069
     End of Run Comment:
    Run_type=production,beam_energy=3.481,beam_halfwaveplate=out,beam_polarization=78,beam_raster=on,comment_text=kinematic 3E(e),  production, p_left=2.939,daq_mode=coincidence,leftarm_p=2.939,leftarm_theta=19.47,photonarm_D=5.7,photonarm_angle=65,photonarm_p=420,target_name=LH2R,target_type=15LH2R
     
    
    PRESCALE FACTORS:ps1=100000   ps2=1000000   ps3=300   ps4=100   ps5=1   ps6=1   ps7=2000   ps8=1024   
    
    EVENTS[0]: 986466       [+]: 484100       [-]: 481693       
    TIME  [0]: 11.536 mins  [+]: 5.661 mins  [-]: 5.661 mins  
    LIVE  [0]:  81.21%      [+]:  81.26%      [-]:  81.25%      
    
    TRIGGER RATES:   PRES/REAL
    T1[0] :11.7/1169820.9 Hz   T2[0] : 0.0/1824.0 Hz   T3[0] :11.0/3312.3 Hz   T4[0] : 8.6/864.3 Hz   T5[0] :1711.9/1711.9 Hz   T6[0] : 1.0/1.0  Hz   T7[0] : 9.7/19316.5 Hz   T8[0] : 1.0/1024.0 Hz   
    T1[+] :11.7/1167884.2 Hz   T2[+] : 0.0/1818.2 Hz   T3[+] :11.0/3312.3 Hz   T4[+] : 8.6/864.7 Hz   T5[+] :1711.0/1711.0 Hz   T6[+] : 0.9/0.9  Hz   T7[+] : 9.7/19331.6 Hz   T8[+] : 1.0/1024.0 Hz   
    T1[-] :11.6/1164906.6 Hz   T2[-] : 0.0/1803.6 Hz   T3[-] :11.0/3307.6 Hz   T4[-] : 8.6/862.5 Hz   T5[-] :1702.2/1702.2 Hz   T6[-] : 1.0/1.0  Hz   T7[-] : 9.6/19282.4 Hz   T8[-] : 1.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1[0] :   8097/809718287  T2[0] :      1/1262527  T3[0] :   7642/2292663  T4[0] :   5982/598259   T5[0] :1184919/1184919  T6[0] :    670/670      T7[0] :   6685/13370372  T8[0] :    692/708785   
    T1[+] :   3966/396662058  T2[+] :      0/617551   T3[+] :   3749/1124999  T4[+] :   2936/293694   T5[+] : 581127/581127   T6[+] :    320/320      T7[+] :   3282/6565821  T8[+] :    339/347793   
    T1[-] :   3957/395704214  T2[-] :      0/612650   T3[-] :   3745/1123557  T4[-] :   2929/292965   T5[-] : 578228/578228   T6[-] :    349/349      T7[-] :   3275/6550005  T8[-] :    339/347840   
    
    AVERAGE CURRENT
    BCM x1 : 27.5594uA  BCM x3 : 27.6132uA  BCM x10: 27.5937uA  
    
    APPROXIMATE CURRENT ASYMMETRIES
    BCM u1 :     1031 ppm     BCM u3 :     1005 ppm     BCM u10:     1014 ppm     
    BCM d1 :     1036 ppm     BCM d3 :    989.3 ppm     BCM d10:     1003 ppm     
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 [0]:0.01861        BCM u3 [0]:0.01868        BCM u10[0]:0.01871        
    BCM u1 [+]:0.009139       BCM u3 [+]:0.009172       BCM u10[+]:0.009186       
    BCM u1 [-]:0.009122       BCM u3 [-]:0.009154       BCM u10[-]:0.009169       
    
    BCM d1 [0]:0.01954        BCM d3 [0]:0.01955        BCM d10[0]:0.01949        
    BCM d1 [+]:0.009597       BCM d3 [+]:0.009601       BCM d10[+]:0.009573       
    BCM d1 [-]:0.009578       BCM d3 [-]:0.009584       BCM d10[-]:0.009556       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3069 at Sun Feb 24 16:53:55 EST 2002
    Left Arm D1 momentum : 2.93899
    Left Arm arm angle : 19.4697
    Tiefenbach Hall A energy : 3477.94
    Left Arm arm mispointing (HPT) : -0
    Left Arm Top VDC Current : -3.61328
    Left Arm Bottom VDC Current : 1.85547
    Left Arm Q1 power supply current : 2211.05
    Left Arm Q1 momentum : 2.93894
    Left Arm Q1 gauss meter : 0.18748
    Left Arm Q1 power supply polarity : 1
    Left Arm Q2 power supply current : 1265.29
    Left Arm Q2 momentum : 2.93844
    Left Arm Q2 gauss meter : -0.6662
    Left Arm Q2 power supply polarity : 0
    Left Arm D1 power supply current : 1026.73
    Left Arm D1 momentum : 2.93899
    Left Arm D1 NMR : 1.0882
    Left Arm Q3 power supply current : 1170.12
    Left Arm Q3 momentum : 2.93912
    Left Arm Q3 gauss meter : 0.5858
    Left Arm Q3 power supply polarity : 0
    Average current of the two cavities : 29.7611
    Current on Unser monitor : 37.9297
    Current on Upstream bcm : 29.6431
    Current on Downstream bcm : 29.8792
    Upstream Cavity Coefficient : 76.7
    Downstream Cavity Coefficient : 78.9
    Current on IBC0L02 (source) : 29.8368
    MBSY1c Hall A Beam energy : 3483.85
    MBSY1c magnet current (amp) : 145.101
    MBSY1c Bdl : 869400
    MBSY3c Hall C Beam energy : 5768.48
    Tiefenbach Hall A energy : 3477.94
    Tiefenbach Hall C energy : 5752.01
    Delta(E)/E width (MV_AI_DXWID) : 0.412155
    IPM1C12.XPOS : -0.184744
    IPM1H04A.XPOS : 0.346048
    IPM1H04A.YPOS : 0.352239
    IPM1H04B.XPOS : 0.0214906
    IPM1H04B.YPOS : 1.65422
    Left Arm Arm Collimator : 0.868604
    HacL_HPE1313A:0_Ch58 : -0.114746
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : -0.0820312
    HacL_alignROLL : 0.260949
    HacL_alignPITCH : -0.164359
    HacL_alignHPT : -0
    Left Arm Arm Collimator : 0.868604
    Wien angle : 60.4311
    Helicity Mode ON/OFF Random/Toggle : OFF
    Wien BDL : 1378.6
    Wien field : 40.248
    Laser attenuation Hall A : 414
    Laser power Hall A : 71
    Half-wave plate (off=out) : OUT
    Beam Half-wave plate (off=out) : OUT
    Target OTR x-position : 0.349299
    Target OTR y-position : 2.11942
    Target OTR x-width : 0.890512
    Target OTR y-width : 0.967559
    Target OTR data valid flag : Yes
    Target OTR In/Out :
    Arc OTR x-position : -0.747276
    Arc OTR y-position : 0.307894
    Arc OTR x-width : 4.3983
    Arc OTR y-width : 3.54175
    Arc OTR data valid flag : No
    Arc OTR In/Out : OTR is Out
    Current Setpoint : 600
    Current Readback : 600.407